Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

Operation and Installation Manual
2013 Cervis, Inc.
59
19.0 IN0450P Option
19.1 Description
The IN045P card when connected to the LR70 0–3V analog input, allows frequency
measurement conversion of a pulse generator operating between 0-450Hz. The card supplies a
+ 12VDC output used to provide power to the sensor. As a frequency to voltage converter,
feedback from an anemometer providing a pulsed signal is displayed providing real-time wind
speed information.
Card Technical Specifications
Figure 35. IN0450P Specifications
Characteristic
Detail
Max. Resolution
8 bits
Input Frequency Range
0 – 450Hz
Operating Temperature Range
-20ºC @ +70ºC
Isolation
Galvanically isolated from main logic board (LR70)
Figure 36. IN0450P
+12VDC OUT
Pulsed Signal IN
GND