Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

Operation and Installation Manual
2013 Cervis, Inc.
67
22.1 A1P4RCAN Connection and Jumper Configurations
22.1.1 LR72 Electrical Connection
The Expansion is connected to the LR72 board using the 2-pin RL4 connector for the 8-30V (+VI
and GND) power supply, and the 5-pin RL3 connector for the CAN Bus connection. See Figure
45.
Table 26. LR72 CAN Connections
Pin
Name
Function
1
CNDCAN Ground
2
CANL CANL bus signal (CAN Low)
3
SHLCAN Shielding
4
CANH CANH bus signal (CAN High)
5
VCAN Power Supply
Figure 45. A1P4RCAN Terminal Connections
Cod. 1141684: TM70 1M abatable base
Cod. 1184005: UNEX 2221-0 clip
Cod. 1095040: CAN RC70 1 expansion cable
Cod. 1131030: M3x6 C/R DIN84 screw
Cod. 2303908: A1P4RCAN electronic board