Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
82
25.2 Menu 3.1 Adjust
Note: It is important to remember to Confirm/Validate each setting adjustment for each
parameter in each semi-axis before going back or exiting the menu. If the desired setting is
not confirmed before leaving the currently displayed changed parameter, the desired setting
is lost; it will not be available to be saved to the EEPROM.
Once all desired parameter settings are made, you must use the 4. SAVE ALL menu to
record all changed settings to the EEPROM.
25.2.1 Parameter Response Type
The graph in Figure 56 shows the different response types that can be chosen for the parameter
action.
Figure 56. Parameter Configuration Options
In this menu, the user is asked to select the output response. Outputs associated with the
selected response type are displayed as follows:
X EXP_TYPE Y
Where:
X is the Number of the analog output
Y is the Output Number of the output
EXP_TYPE is the type of analog output (A1P4CAN, A2VCAN, or A2ICAN)
The user must select which output to tele-adjust. The chosen output should be flashing. If two
outputs display, use the UP/DOWN keys to select the desired output and confirm the selection
by pressing START. The selected output will briefly display.
Szero
Type