Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
90
R70/XX Specifications
Table 46. v3.2 R70/XX Specifications
R70/XX
Specifications
Available frequencies (ISM bands)
915MHz
870MHz/433MHz
419MHz
AC current power supply range
48V/115/230v AC 50/60Hz (+15% / -20% Vin)
DC current power supply range
8-32v DC
Ingress protection
IP65 / NEMA-4
Antenna
External (standard)
Working frequency channel selection
Fix or automatic (listen before talking EEPROM)
Weight
Maximum = 7 Kg (53 relays)
Dimensions
Length = 350 mm / Wide = 250 mm / Heigth = 150mm
EEPROM
Internal and extractable (EP70)
Signaling
MultiLED: internal LEDs
Connections
External input/output terminal plugs for using with cable
glands and base panel connectors
Maximun current over resistive load
6ª
Operating temperature
-20ºC / +70ºC (-4ºF / 158ºF)
Storage temperature
-25ºC / +75ºC (-13ºF / 167ºF)
Storage temperature –long periods-
-25ºC / +55ºC (-13ºF / 131ºF)
Maximun comsumption
40 VA