Instruction manual
24
to the desired number with the up arrow (↑) or down
arrow (↓).
A list of all parameter numbers is included in Table 3-3
and 3-4 to serve as a quick reference during operation.
Parameters that can only be displayed are numbered 01
through 25. The remaining parameters can be modified
from the keypad. Parameters that can be downloaded
through a serial interface are numbered 30 through 43.
Some parameters have built in limits. Refer to Table 3-2
for the parameter numbers have limits set.
Parameter Limits Table 3-2
Parameter
Number Parameter Description Limits Units
26 Maximum Speed Speed of press SPM
30* Angle No. 1 0 - 359.9 Degrees
31* Speed No. 1 Speed of press SPM
32* Angle No. 2 0 - 359.9 Degrees
33* Speed No. 2 Speed of press SPM
34* Angle No. 3 0 - 359.9 Degrees
35* Speed No. 3 Speed of press SPM
36* Angle No. 4 0 - 359.9 Degrees
37* Speed No. 4 Speed of press SPM
38* Angle No. 5 0 - 359.9 Degrees
39* Speed No. 5 Speed of press SPM
40* Angle No. 6 0 - 359.9 Degrees
41* Speed No. 6 Speed of press SPM
42* Creep Angle Degrees
43* Stop Angle 5 Degrees
44 Creep Speed 5 SPM
45 Micro Inch Speed 25% of max. SPM
46 Inch Speed 50% of max. SPM
47 Inch Accel Rate 1 - 100 SPM/Sec.
48 Initial Value of Linear Accel Ramp 0 - 3 SPM
49 Initial Accel Rate 1 - 100 SPM/Sec.
50 Operating Accel Rate No. 1 1 - 100 SPM/Sec.
51 Operating Accel Rate No. 2 1 - 100 SPM/Sec.
52 Operating Accel Rate No. 3 1 - 100 SPM/Sec.
53 Accel Rate Delta SPM No. 1 1 - 5 SPM
54 Accel Rate Delta SPM No. 2 1 - 5 SPM
55 Operating Decel Rate No. 1 1 - 100 SPM/Sec.
56 Operating Decel Rate No. 2 1 - 100 SPM/Sec.
57 Operating Decel Rate No. 3 1 - 100 SPM/Sec.
58 Decel Rate Delta SPM No. 1 1 - 5 SPM
59 Decel Rate Delta SPM No. 2 1 - 5 SPM
70 Wrong Direction Limit 0 - 10 Degrees
NOTE: *These parameters can be downloaded through a serial interface.