Typical DMR Parameter and Fault Number Reference Chart Table 3-3
PARAMETER PARAMETER PARAMETER PARAMETER
NUMBER NUMBER
00 Not Used 72 No. Of Speed Feedback Periods
01 Average Speed Feedback - SPM 73 Serial Interface Baud Rate
02 Speed Reference - SPM 74 Under-speed % Limit
03 Average Speed Error (+/-) - SPM 75 Die Contact Angle
04 Effective Resolver Position 76 Resolver Direction Selection
05 AC Line Voltage - Volts 77 Resolver Offset Angle
06 Not Used 78 Gear Ratio
07 Not Used 79 Pulses per Rev.
08 Clutch Current Feedback - Amps 80 Pot. Selector
09 Brake Current Feedback - Amps FAULT NUMBER FAULT
10 EPROM 0101 Over-speed
11 Part Number 0202 Loss of Tach
12 Speed at Die Contact Angle - SPM 0208 Clutch Current Delay
13 Serial Interface Data Received 0206 Press Movement in Wrong Direction
14 Analog Speed Reference 0207 Loss of Line
15 Average Parts per Minute 0208 Enable without Clutch On
16 Clutch Current Timer – SEC 0209 Cl. Contactor On After Cl. On De-energized
17 Brake Current Timer - SEC 0210 Missing Enable
18 CL-BR Coil Cool Down - SEC 0211 Inch + Micro Inch + Enable
19 Under-speed Timer - SEC 0212 Reverse Command
20 Over-speed Timer - SEC 0220 Enable Present After Normal Stop
21 Not Used 0221 Clutch Contactor Not On in Test Mode
22 Actual Resolver Position 0222 Press Movement in Test Mode
23 Main Program Loop Ctr. 0223 Enable Present in Test Mode
24 Present Pr. Fault Codes 0224 Stop-On-Top Not Performed
25 Previous Pr. Fault Codes 0225 Cl. Contactor On Removed w/o Removing
26 Max. Pr. Run Sp. – SPM Enable or During 450 ms Time Delay
27 Max AC Line Voltage 0226 Clutch Contactor On w/o Enable
28 Max. Cl. Cur. Scaling Factor – Amps 0227 Enable Before Cool Down Expired
29 Max. Br. Cur. Scaling Factor – Amps 0228 Creep Sp. Not Reached Before Stop Angle
30 Angle 1 - DEG 0313 Under-speed
31 Speed 1 - SPM 0314 Clutch and Brake Current Overlap
32 Angle 2 - DEG 0315 Clutch Current
33 Speed 2 - SPM 0316 Brake Current
34 Angle 3 - DEG 0317 Inch Change
35 Speed 3 - SPM 0318 Micro Inch Change
36 Angle 4 - DEG 0319 Reverse Change
37 Speed 4 - SPM 0329 Parameter Out of Limits
38 Angle 5 - DEG SIGNALS FOR CHART
39 Speed 5 - SPM RECORDER
40 Angle 6 - DEG TERMINAL FUNCTION
41 Speed 6 - SPM 337 Common
42 Stop-On-Top Creep Sp. Angle - DEG 338 Speed Reference
43 Stop-On-Top Apply Br. Angle - DEG 339 Clutch Current
44 Creep Speed-Top - SPM 340 Brake Current
45 Micro Inch Speed - SPM 341 Speed Feedback
46 Inch Speed - SPM FAULT INDICATOR
47 Inch Accel Rate – SPM/SEC NUMBER FAULT
48 Initial Accel Step – SPM - Run Signal is Present
49 Initial Accel Rate – SPM/SEC 0 Push Reset
50 Run Accel Rate 1 – SPM/SEC 1 External
51 Run Accel Rate 2 – SPM/SEC 2 Brake Free Wheel
52 Run Accel Rate 3 – SPM/SEC 3 Low Line
53 Run Accel Delta 1 – SPM/SEC 4 Brake Over-current
54 Run Accel Delta 2 – SPM/SEC 5 Clutch Free Wheel
55 Run Decel Rate 1 – SPM/SEC 6 Line/Microprocessor
56 Run Decel Rate 2 - SPM/SEC 7 Clutch Over-current
57 Run Decel Rate 3 - SPM/SEC
58 Run Decel Delta 1 – SPM/SEC
59 Run Decel Delta 2 – SPM/SEC
60 Test Mode
61 Clutch Test Mode
62 Brake Test Mode
63 Clear Faults
64 Cl. Cur. On too Long Timer - SEC
65 Br. Cur. On too Long Timer - SEC
66 Cl/Br Coil Cool Down Timer - SEC
67 Under-speed Timer - SEC
68 Over-speed Timer - SEC
69 % Over-speed - %
70 Wrong Direction Limit - DEG
71 Display Update Time - SEC