Emergency Power Supply for the OMEGA ACTIVE-System Operating Instructions
Preface Preface These Operating Instructions will help you using the Emergency Power Supply as intended, safely, and advantageously. Any person who operates or disposes of the Emergency Power Supply must have read and understood the entire contents of these Operating Instructions and other required user manuals, operating and assembly instructions.
Contents Contents Preface............................................................................ 2 Notes on the layout .......................................................... 2 For your safety ................................................................. 4 Basic safety instructions ......................................... 4 Notes on the handling of batteries .................................. 6 Explanation of the safety notes ...................................... 7 Intended use ..............
For your safety For your safety Basic safety instructions Observe all warnings and notes in these Operating Instructions when you assemble, program, and use components of the system. To prevent danger to life and limb, the following safety instructions must be observed: Danger to life Make sure that the effects of your programming do not expose any persons to any risk of injury or other hazards. Satisfy yourself that your programming translates into the desired function.
For your safety Danger of poisoning Always keep the system components out of reach of children. There is a risk that children swallow small parts such as batteries or screws. Danger of property damage To prevent property damage, the following safety instructions should be observed: Always have repairs performed by properly qualified personnel. Only use accessories and spare parts recommended by CEStronics. Do not drop the Emergency Power Supply on the floor, on hard surfaces or on hard objects.
For your safety Notes on the handling of batteries Keep batteries out of reach of children. If a battery was swallowed, consult a physician without delay. Always insert new batteries. Never insert old and new batteries at the same time. Never mix the battery types. Always replace batteries by batteries of the same or an equivalent type. Before inserting the batteries, check that the terminals in the device and at the batteries are clean. Clean them if necessary.
For your safety Explanation of the safety notes These Operating Instructions include safety notes of the following types: ATTENTION ATTENTION notes warn against possible property or environmental damage. Intended use The Emergency Power Supply is intended for the emergency opening of locking cylinders of the OMEGA ACTIVE system. Any other use is considered to be improper and may result in property damage or even personal injury.
Description Description The Emergency Power Supply serves for the emergency opening of locking cylinders of the OMEGA ACTIVE system in case of flat batteries. The Emergency Power Supply also allows you to update the firmware of your locking cylinders. The Emergency Power Supply has its own power supply comprised of four commercial rechargeable or nonrechargeable AA batteries to supply locking cylinders with power. This power supply is sufficient for about thirty emergency opening operations.
Scope of delivery Scope of delivery Before fitting and commissioning, please check the contents of the package and the scope of delivery. Check new devices for transport damage and inform your dealer promptly if any damage is found.
Operation Operation Inserting the batteries The four supplied batteries must be inserted into the Emergency Power Supply. For this purpose, remove the cover of the battery compartment on the rear of the Emergency Power Supply. Insert the four batteries into the battery compartment. Make sure that you insert them with the correct polarity. Push the cover again over the battery compartment. The Emergency Power Supply is now operative.
Operation Performing the emergency opening ATTENTION After an emergency opening, the locking cylinder is no longer secured. In this case, you can no longer lock the locking cylinder from the outside. You can only lock the locking cylinder after you have inserted a new battery. Always insert a new battery into the battery compartment of the locking cylinder after each emergency opening.
Operation For an emergency opening of your locking cylinder, proceed as follows: Release the two opposite screws on the outside knob with the combination tool (three-square screwdriver). These screws cannot be completely screwed out but will always be held in the outside knob.
Operation Pull the reader module out of the outside knob until you feel the stop (1.). Connect the Emergency Power Supply with the interface (2.) at the reader module. The LEDs in the reader module light up green to signal the connection with the Emergency Power Supply. Wait a couple of seconds before you continue. Use your authorized locking medium to open the door. Rotate the outside knob of the locking cylinder by at least one notch.
Operation Push the reader module back into the sleeve of the outside knob. To fasten the reader module, hand-tighten the two opposite screws with the combination tool (three-square screwdriver). This completes the emergency opening.
Operation Updating the firmware To transmit new firmware updates, you require a PC (option) with a free COM port. Firmware updates are transmitted to the locking cylinder with the "OMEGA ACTIVE Firmware-Update" software. ATTENTION If you separate the power supply during the update process, the update will not be transmitted and the process must be started anew. Make sure that the connection between the locking cylinder and the Emergency Power Supply is not interrupted.
Operation To transmit firmware updates with "OMEGA ACTIVE FirmwareUpdate" into the locking cylinder, proceed as follows: Connect the Emergency Power Supply with a free COM port of your PC. Start the "OMEGA ACTIVE Firmware-Update" software on your PC, by selecting: - Start > Programs > OMEGA/OMEGA Active Firmware Update Wait until the following message appears. Select the device for which you want to perform the update. Select the COM port. Perform an authorization with your SYSTEM-MASTER.
Operation Push the "Software Update" button on your Emergency Power Supply. The update starts and the PC monitor shows the progress of the updating process. After the update has been transmitted successfully, the following message appears: Separate the connection between the locking cylinder and the Emergency Power Supply. Separate the connection between the Emergency Power Supply and your PC.
Operation Close the "OMEGA ACTIVE Firmware-Update" software. Push the reader module of the locking cylinder back into the sleeve of the outside knob. Hand-tighten the two opposite screws with the combination tool (three-square screwdriver). This completes the firmware update.
Service and maintenance Service and maintenance Have the Emergency Power Supply serviced and its perfect functioning verified every six months by CEStronics or a CEStronics partner. Replace the batteries in line with a defined maintenance schedule for the Emergency Power Supply. Make sure you have replacement batteries ready in good time. Trouble shooting Symptom Emergency opening is not possible. Possible cause and remedy The batteries of your Emergency Power Supply are flat.
Trouble shooting Symptom Firmware update is not possible. Possible cause and remedy The SYSTEM-MASTER is not authorized for the locking cylinder concerned. Use the SYSTEM-MASTER authorized for the locking cylinder concerned. The batteries of the Emergency Power Supply are flat. Check the batteries of the Emergency Power Supply. Your COM port does not work properly. Verify the functioning of your COM port. If the trouble still cannot be eliminated, please contact your CEStronics partner.
Disposal Disposal Neither the Emergency Power Supply nor any of its components may be discarded with the normal household waste. Ask your local authorities about recycling and/or proper disposal in line with environmental regulations. Our packaging is made of environmentally friendly, reusable materials. These are external packaging and inserts made of cardboard, inserts and protective film made of polypropylene (PE).
Technical data Technical data Dimensions: Power supply: Ports: Length: approx.130 mm Width: approx. 70 mm Height: approx. 25 mm 4 1.5 V AA type batteries - 1 plug for connection with the locking cylinder - 1 RS 232 for connection with COM port (SUB-D, 9-pole) Length of connection cable: Approx.
Glossary Glossary Emergency opening Opening of a locking cylinder in case of a flat battery. The required power is provided by the Emergency Power Supply. Firmware The "operating system" of your locking cylinder. To benefit from further developments in the firmware, an occasional update of the firmware is recommended. SYSTEM-MASTER The optional SYSTEM-MASTER is used to define the allocation to a locking system. The SYSTEM-MASTER grants all highest-level authorizations.
Notes on the manufacturer's warranty Notes on the manufacturer's warranty The manufacturer's warranty does not cover: damage to outer mechanical parts and damage resulting from normal wear and tear damage as a consequence of external events or influence damage as a consequence of improper operation damage as a consequence of excess voltage damage as a consequence of fire, water or smoke batteries.
The information and data contained in this document are subject to change without notice. Without the express written permission by CEStronics, no part of this document may be copied or transmitted for any purpose. © 2008 CEStronics, Velbert November 2008 BRO 2214-001, V 1.2, 09/2012 CEStronics GmbH Friedrichstr. 243 42551 Velbert, GERMANY Phone: +49 2051-204-0 Fax: +49 2051-204-229 www.ces.