User`s guide

10 Intel® RAID Controller RS2SG244 Hardware User’s Guide
Configuring the RAID Controller
To configure the RAID Controller, follow these steps:
1. Turn on the system power and check to make sure that the SAS/SATA devices
power up before or at the same time as the system.
2. During the boot, the following BIOS message appears to state the keys that you
need to press to enter the Intel
®
RAID BIOS Console 2, such as:
Press <CTRL><G> to run BIOS Console 2.
This message times out after several seconds. If you miss it, you need to restart the
system.
After you press the keys to enter the Intel
®
RAID BIOS Console 2 software, the
firmware takes several seconds to initialize and then display the Intel
®
RAID
Controller RS2SG244 number and firmware version. The numbering of the RAID
controller follows the PCI slot scanning order used by the server board.
3. See the Quick Start Users Guide and the Software User's Guide for instructions to
configure the RAID controller and to install the operating system drivers.
Replacing a Controller
To replace the RAID controller, see your server system documentation for instructions to
remove and then install an add-in adapter.
Resolving a Config Mismatch
If the newly installed RAID controller was previously configured, a message displays
during POST, stating that there is a configuration mismatch because the configuration data
in the NVRAM differs from that in the hard drives. Use these steps to resolve the
mismatch:
1. Press <Ctrl> + <G> when prompted during boot up to access the BIOS
Configuration Utility
2. Select Configure > View/Add Configuration to see the NVRAM and drive
configurations.
3. If the drives contain the correct configuration, use configuration from the disks.
4. Press <Esc> and select YES to update the NVRAM.
5. Exit and reboot.