As well the wheels on the ramps also roll on the floor when the incline changes. For these reasons it is
essential that these areas are kept clear of dirt and debris.
The treadmill ramps will become dirty and can be simply swept clear or washed with mild soap and
water.
The polycarbonate see-through side panels will become noticeably dirty from dust, sweat, hair, etc.
These panels can be cleaned with mild soap and water. No abrasive materials should be used on the
polycarbonate since the surface will be scratched.
6.3 Lubrication
Belt Lubrication
The
TITAN Trainer
is equipped with an automatic belt lubrication system. A level sensor in the
reservoir indicates when the reservoir requires refilling. The reservoir must be filled with
TITAN Trainer
Belt Lubricant. (Note: See Appendix A for order form.) The reservoir fill cap is located under the operator
control station on the top of the side cover.
Bearing Lubrication
Roll bearings are located at each end of the idler roll and driven roll. The idler roll bearings are
mounted in the roll. Grease fitting access is gained through the access hole in the belt tension adjusting
plates. The driven roll bearing grease fittings are located on the bearing mount pillow blocks. These
bearings require grease lubrication with EP2 grease every six months.
Wheel Bearing Lubrication
Bearings on the lift arm wheels and ramp wheels are lubricated through grease fittings in the axle
bolts. These bearings require grease lubrication with EP2 grease every six months.
Gearbox and Coupling Lubrication
The gearbox oil should never have to be replaced but the level should be checked yearly. If oil is
required it must be filled with MOBIL SHC-634 or equal. The chain coupling between the gearbox and the
drive roll must be sprayed with rust preventative oil every six months.
6.4 Hydraulic Power Supply
The level of oil in the hydraulic power supply must be checked yearly. Top up as required with ESSO