Instruction manual

Wiring
Making the electrical connections
To gain access to the electrical connections, press tabs
(P Fig 12) to release the catches on either side of the
boiler and pivot the electrical box forward.
Remove the two retaining screws (Afig 12), lift the cover
and turn over to reveal an interface PCB and connecting
block (Fig 13).
Connect the live and neutral wires to the connector (D
Fig 13) on the interface PCB leaving sufficient earth wire
to connect to the main earthing point.
The connecting cable for the cylinder thermostat is coiled
behind the temperature adjuster on the cylinder. This
cable is led through the cable clamp on the boiler
electrical box and is connected to connecting block (D)
as shown in Fig 13.
If a room thermostat is to be fitted, the link wire on the
main connector plug (C Fig 13) must be removed and
the room thermostat connected in its place.
These
connections are for use with voltage free switching.
Fig. 12
/Connections Ra
Fig. 13