Instruction manual

Switching On
1. Check that the gas service tap is opened at the
gasmeter and main power is on.
2. Check that pressure in central heating system is
above 0.7 bar and below 2.5 bar with the pressure
gauge @ (26).
3. Open the gas tap (27) by turning from right to left.&
4. The boiler is now ready to use.
Heating
1. Turn selector switch (19) fully clockwise to position
‘1111 The green ‘power on’ indicator (‘J will light.
2. If the room thermostat (if fitted), the boiler
temperature control ‘~~~~ and the clock (if fitted) are
all calling for heat, the orange ‘burner on’ indicator
@ will light and the heating will be on.
Note: If the boiler has been turned off for some time the
first attempt to light it may result in a lockout j& . If this
happens press the reset button (25) and the boiler will
light.
Hot Water
Turn selector switch (19) clockwise from the ‘off position
to the first setting (hot water only) 2 or the second
setting (heating and hot water) ‘1111 /x\c . The green
indicator 8 will light.
Turn the temperature selector on the cylinder fascia
panel (44) to the desired position.
If the cylinder thermostat is calling for heat, the orange
‘burner on’ indicator 0 will light and the water in the
cylinder will begin to heat up.
To Turn Boiler Off Completely
1. Turn the selector switch (19) to the off position
l
2. Turn the gas tap (27) from left to right STOP’.