Operating instructions

Making the Electrical Connections
Hinge down the electrical box to gain access to the
electrical connections. Push in the tabs (P fig. 19) on
either side of the boiler and pivot the box forward.
Undo the two retaining screws, remove cover and
remove cable clamp. (A fig. 19)
Connect the live and neutral wires to the multipin plug
leaving sufficient earth wire to connect to the earthing
point. (B fig. 20).
Note: The connections should be made so that should
the lead be pulled from its anchorage, the current
carrying wires become taut before the earth wire.
Fig. 19