User`s manual

13
T
he water heater must only be installed with a flue supplied by the manufacturer.
These kits are supplied separately to the appliance in order to respond to different installation solutions. For more information
w
ith regard to the inlet/outlet accessories consult the flue brochure and the following instructions. The water heater is supplied
ready for connection to a concentric gas intake and exhaust duct system.
WARNING!!
The exhaust gas ducts should not be in contact with or close to inflamma-
ble material and should not pass through building structures or walls made
of inflammable material.
W
hen replacing an old appliance, the flue must be changed.
IMPORTANT!!
Ensure that the flue is not blocked.
E
nsure that the exhaust gas ducts do not
have leaks
Ø 60/100 mm
CONTENTS:
1
X SILICONE O-RING (60mm)
1
X ELBOW (90
O
)
2
X WALL SEALS (INTERNAL &EXTERNAL)
1
X FLUE PIPE INCLUDING TERMINAL (1 METRE - 60/100)
2X FLUE CLAMPS
4X SCREWS
2x Seals
Once the w
ater heater has been positioned on the w
all, insert
the elbow into the socket and rotate to the required position.
NOTE: It is possible to rotate the elbow 360
o
on its vertical axis.
If necessary, fit the restrictor ring (see Fig. 12 and Table on
P
age 18).
Using the flue clamp, seals and screws supplied
(Figs. 11 &
13)
secure the elbow to the boiler.
The 1 metre hor
iz
ontal flue kit (3318000) supplied is suitable
f
or an exact
X dimension of 823 mm.
Measure the distance from the face of the e
xter
nal w
all to the
f
ace of the flue elbo
w
(X -
Fig 11
),
subtr
act 48 mm from this
measurement, y
ou now have the total length of flue required
(including the terminal), this figure must now be subtracted
from 907mm, you now have the total amount to be cut from the
plain end of the flue
.
Cut the flue to the required length ensuring that the distance
between the inner and the outer flue is maintained
(Fig 14).
Fig. 11
4.1 Fitting the Coaxial Flue (
Ø
60/100 Horizontal)
4. FITTING THE FLUE
WARNING!!
Consult the table on Page 18, to see if a restrictor is
required for the type of flue system being used. Should it
be necessary to fit the restrictor, it must be fitted as shown
in
Fig.
12
.
Coaxial
Fig 12