4.5 Permissible Flue Lengths
The Ø 85 diaphragm is included in the accessories kit with the SX 14FF model.
NO
TE
: DRA
WINGS
ARE
INDICA
TIVE
OF
FLUEING
OPTIONS
ONLY
.
TYPE 1
TYPE 5
TYPE 4
TYPE 3
TYPE 2
4.6 Flue Types
Fig. 24
SX 14 FF
Exhaust Type
Use the
ø 85 mm
Restrictor
Do not use the
Restrictor
Maximum Flue
Length
Reduction for
90
o
Bend
Reduction for
45
o
Bend
Coaxial
S
ystems
ø 60/100
Type 1
Between
0.3 m / 1 m
1 m - 3 m 3 m 1 m 0.5 m
Type 2
Between
0
m / 1.5 m
1.5 m - 4 m 4 m 1 m 0.5 m
Type 3
Between
0 m / 1.5 m
1.5 m - 4 m 4 m 1 m 0.5 m
Coaxial
Systems
ø 80/125
Type 1
Between
0.3 m - 2 m
2 m - 6 m 6 m 1 m 0.5 m
Type 2
Between
0 m - 2 m
2 m - 6 m 6 m 1 m 0.5 m
Type 3
Between
0 m - 2 m
2 m - 6 m 6 m 1 m 0.5 m
SX 14 FF
Exhaust Type
Use the
ø ?? mm
Restrictor
Do not use
the Restrictor
Maximum
Flue Length
Reduction for
90
o
Bend
Reduction for
45
o
Bend
Twin Pipe
Systems
ø 80/80
Type 4
Between
0 m - 3 m
Between
3 m - 10 m
10 m 1.4 m 2 m
Type 5
Between
0 m - 3 m
Between
3 m - 10 m
10 m 1.4 m 2 m