MODEL NO. HTJ-2027 3.2L ULTRASONIC HUMIDIFIER INSTRUCTION MANUAL Important - Please read these instructions carefully before first using this product and retain for future reference.
SAFETY INSTRUCTIONS 1. Install the appliance on a flat and firm surface to avoid vibration and noise. 2. Never immerse the appliance in water or other liquids. 3. Never operate this appliance if the cable or connector is damaged or if there is any abnormal operation. 4. Unplug the appliance during filling and cleaning. 5. Disconnect the appliance from the mains when it is not in use. 6. Operate the appliance only at a mains supply of 220-240V~50/60Hz 7. This appliance is for indoor use only. 8.
13. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in safe way, and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 14.
CAUTIONS When using this humidifier, please comply with the following safety measures: ⚫ Carefully read all the instructions, even if you are very familiar with this product. ⚫ This humidifier is designed for use in the UK; if used in any other country please check your supply voltage is compliant with product specifications. ⚫ Please do not use the humidifier in drafty areas and radiation areas. ⚫ Do not use within proximity (<1 meter) of a bed as this can cause dampness to the bedding.
⚫ Do not put chemicals, detergents into the atomiser as dangerous vapors can be emitted. ⚫ While the unit is operating, do not move it otherwise water spillage and contamination of the lower base unit may cause serious damage. ⚫ If the temperature is likely to fall below 0°C the unit must be fully emptied. ⚫ Never turn whole unit upside down while on or off, water contamination or atomizer chip damage could occur.
KNOW YOUR APPLIANCE 1. Mist cover 2. Water tank 3. Base (including water reservoir) 4. Control Knob 5. Main Power switch First time use Filling the water tank: We recommend using distilled water to avoid limescale build-up but if using tap water in a hardwater area we recommend regular cleaning to avoid limescale build-up. Make sure water temperature does not exceed 40°C. (Put the appliance down on a suitable flat horizontal surface, and where it is to be used.
Take off the nozzle Lift off water tank Turn over, unscrew the cap 4. Fill from the tap or distilled water container to the top of upturned tank or as much as required 5. Replace filler cap/filter assembly. Fill (tap or Jug) Fasten the cap Fit tank to base as align marks Align marks 6. Turn the tank over and wipe away any spilt water, carefully fit the tank onto the base, taking care to align correctly noting the alignment marks on the base unit and tank. 7.
Note: If the indicator light is Red, water is still filling the water reservoir (in the base unit), wait until it turns Blue, the unit will start working. Warning: Whenever a filled water tank is fitted to the top of the white base, water will flow into the water reservoir below, filling it to the brim with water, make sure not to spill by lifting and tilting it! In use: Turn control knob (4) to set the vapor release rate depending on requirement, including dryness or size of room.
CLEANING Always unplug the unit from the mains before commencing any cleaning in order to avoid the risk of electric shock. Tank cleaning Remove the water tank (2) from the unit and unscrew the water cap. Wipe away any limescale present with a clean soft cloth then wash it with clean water. We recommend cleaning the water tank every 2 to 3 weeks. Water reservoir cleaning If there is any limescale in the water reservoir, wipe it with a soft cloth and wash it with clean water.
Maintenance of Water Filter Remove the water filter from the unit by unscrewing. Wash the filter in warm soapy water and rinse thoroughly. Refit the water filter. STORAGE If not using the unit for an extended period of time, please: o Turn the unit off and unplug it from the mains. o Completely empty the water tank and wipe it clean. o Completely drain the base unit and wipe dry o Cover the unit and store away from direct sunlight.
TROUBLE SHOOTING Never try to repair or dismantle the humidifier yourself. Incompetent repairs result in loss of warranty and can endanger the user and property. PROBLEM Lots of water resting below water tank after use and when refill is needed. No operation and no lights Blue light, no vapour Vapour has bad odour Small amount of vapour CAUSE This is normal, use a towel when refilling and be careful if moving unit, also see section on how to refill with water.
SPECIFICATIONS Product Name Model Rated voltage Rated power Water tank capacity Rating Humidity Ultrasonic Humidifier HTJ-2027 220-240V~50/60Hz 18-25W 3.2L 250ml/hr RECYCLING ELECTRICAL PRODUCTS You should now recycle your waste electrical goods and in doing so help the environment. This symbol means an electrical product should not be disposed of with normal household waste. Please ensure it is taken to a suitable facility for disposal when finished with. Visit www.recycle-more.co.
CONNECTION TO POWER • • • • Before connecting, check that the voltage indicated on the appliance corresponds with the mains voltage in your home. If this is not the case, consult your dealer and do not use. This appliance may be fitted with a non-rewirable plug. If you need to change the fuse in a non–rewirable plug, the fuse cover must be refitted. If the fuse cover is lost or damaged, the plug must not be used until a replacement is obtained.
Issue 4 19/8/2021 14