Installation Manual

25
PROGRAMMINGPROGRAMMING
PROFILE SELECTION
To simplify installation this operator contains preset defaults called
profiles. Each profile contains the manufacturer’s recommended
initial settings for a particular operator model.
These profiles allow an installer to quickly set up a door.
After a profile has been loaded the controller can be further
adjusted to meet a specific customer’s requirements as needed,
such as timer settings, input configurations and other options.
NOTE: Loading a profile will cause all related parameters to be
overwritten with the defaults of the loaded profile!
RESET DEFAULTS
To reset a controller to factory default values use menu path:
Operating Modes – Reset Defaults
NOTE: Learned radio devices and cycle counters are not affected
by Reset Defaults
PARAMETER DEFAULT VALUE
Operating Mode B2
Frequency Profile TBD
Open Frequency TBD
Close Frequency TBD
Limits Must relearn limits
LMEP LMT Close Limit
EDGE LMT Close Limit
PHOTOEYE LMT Close Limit
Timer to Close 15
Delay to Open 0
Delay to Close 0
Open Alarm 0
Input Stuck Timer 120
INP1 Function No Function
INP1 Logic N.O.
INP2 Function No Function
INP2 Logic N.O.
INP3 Function No Function
INP3 Logic N.O.
LMEP Unlearned
Service Counter Interval 5000
Service Counter Value Is not reset
Absolute Cycle Counter Is not reset
Operating Mode
A B
C D