Installation Manual

27
PROGRAMMING / FREQUENCY PROFILES
The controller contains three preconfigured frequency profiles that
control the motor speed, as well as the acceleration and deceleration
ramps. These profiles cannot be manually altered. If accelerations or
decelerations are too high, reduce the frequency profile to a lower
setting.
Medium is the default setting for all profiles.
FREQUENCY (SPEED) PROFILE SETTINGS
DIRECTION LOW MEDIUM HIGH
Open 30 60 90
Close 30 40 60
To Change the frequency profile setting, select Operating Modes –
Freq. Profiles.
Freq. Profiles
Low
Medium
High
A checkbox indicates which frequency profile is currently active.
Choose either the Low, Medium or High setting.
The screen will display Loading Frequency Profile and then return to
the top menu.
Loading
Frequency
Profile
PROGRAMMING
SETTING THE OPEN MID-STOP
This operator allows for the programming of a single mid-stop door
position.
To set the open mid-stop position:
1. In Programming Mode, go to Door Postion => Open Mid-Stop or
Close Mid-Stop.
2. Use the Up/Down buttons to move the door to the desired
position.
3. Save = Enter
To erase the mid-stop, select Erase Open Mid-Stop or Erase Close-
Mid Stop option. Save=Enter.
NOTE: Restoring defaults or resetting limits will erase the mid-stop
position.
THIS SECTION REQUIES NEW
PROFILE DETAILS FROM TEAM