DETERMINE AND SET OPERATING MODE
Select the operating mode for your application from the menu in the controller, see page 24.
WIRING TYPE DEVICE ACTION STATE RESPONSE
C2
Momentary
contact to open
and stop with
constant pressure
to close (wired
devices ONLY),
open override plus
wiring for sensing
device to reverse.
Open Mid-Stop
available (jumper
must always be
in place) with
this mode type.
Compatible with
3-Button Station
and Single-Button
Station
Front panel
buttons(membrane)
and 3-Button
Control Station
OPEN button is pressed momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
CLOSE button is pressed momentarily
Operator at OPEN limit Door closes and stops when button is released
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes and stops when button is released
Door stopped during open or close cycle Door closes and stops when button is released
STOP button is pressed momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state
OPEN button is held (constant pressure)
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to OPEN limit (bypasses Mid-Stop)
Door opening No change in state (bypasses Mid-Stop)
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit (bypasses Mid-Stop)
CLOSE button is held (constant pressure)
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
CLOSE button is pressed momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state
STOP button is pressed momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state
Single Button
Remote Control
Programmed as
SBC
Button is pressed
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening Door stops
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open cycle No change in state
Door stopped during close cycle Door opens to the OPEN limit or Mid-Stop
Single Button
Control Station
(Wired)
Button is pressed
Operator at OPEN limit Door closes and stops when button is released
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening Door stops
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open cycle Door closes and stops when button is released
Door stopped during close cycle Door opens to the OPEN limit or Mid-Stop
Button is held (constant pressure)
Door Opening No change in state (bypasses Mid-Stop)
myQ
®
Smart
Facility Access
Open is pressed
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
Close is pressed
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state