DETERMINE AND SET OPERATING MODE (CONTINUED)
WIRING TYPE DEVICE ACTION STATE RESPONSE
B2
Momentary contact
to open,close and
stop, plus wiring
for sensing device
to reverse and
auxiliary devices
to open and close
with open override.
Programmable
Mid-Stop available
(jumper must
always be in place)
with this wiring
type. Compatible
with 3-Button
Station, 1-Button
Station, 1 and
3-Button Remote
Control.
LiftMaster
Monitored
Entrapment
Protection (LMEP)
Device
required.
Front panel buttons
(membrane) and
3-Button Control
Station
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state
OPEN button is held (constant
pressure)
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit (bypasses Mid-Stop)
Door opening No change in state (bypasses Mid-Stop)
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit (bypasses Mid-Stop)
CLOSE button is held (constant
pressure)
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to closest OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit No change in state
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state
Door stopped during open or close cycle No change in state
Single Button
Remote Control
Programmed as
SBC
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening Door stops
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop
Single Button
Control Station
(Wired)
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening Door stops
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop
Button is held (constantpressure)
Door Opening No change in state (bypasses Mid-Stop)
myQ
®
Smart
Facility Access
Open is pressed
Operator at OPEN limit No change in state
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop)
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
Close is pressed:
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit