DETERMINE AND SET OPERATING MODE (CONTINUED)
WIRING TYPE DEVICE ACTION STATE RESPONSE
T
This mode will
attempt to close
the door from any
position
except when fully
closed, or when
a safety input is
present. The Timer
defeat input holds
the timer in reset if
the TTC is running.
Momentary contact
to open, close, and
stop, with open
override and Timer-
To-Close (TTC).
Every device that
causes the door to
open, except any
sensing edge input
device, activates
the TTC. Auxiliary
controls can be
connected to open
input to activate the
TTC. If the TTC has
been activated, the
open button and
radio control can
recycle the timer.
The stop button
will deactivate
the timer until the
next command
input. The TTC will
function from the
Open limit stop
and Open Mid-Stop
available (jumper
must always be
in place) with
this mode type.
Compatible with
3-Button Station,
1-Button Station
and 1 and 3-Button
Remote Control.
LiftMaster
Monitored
Entrapment
Protection (LMEP)
Device required.
Front panel
buttons(membrane)
and 3-Button
Control Station
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state (Recycle timer)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop (and activates TTC)
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) (and activates TTC)
Door at Open Mid-Stop Door opens to the OPEN limit (and activates TTC)
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop (and activates TTC)
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit No change in state (Deactivate timer)
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state (Deactivate timer)
Door stopped during open or close cycle No change in state
OPEN button is held (constant
pressure)
Operator at OPEN limit No change in state (Recycle & hold timer)
Operator at CLOSE limit Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC
Door opening No change in state (bypasses Mid-Stop)
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC
CLOSE button is held (constant
pressure)
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state (Recycle timer)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit No change in state (Deactivate timer)
Operator at CLOSE limit No change in state
Door opening Door stops
Door closing Door stops
Door at Open Mid-Stop No change in state (Deactivate timer)
Door stopped during open or close cycle No change in state
Single Button
Remote Control
Programmed as
SBC
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening Door stops and activates TTC
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Single Button
Control Station
(Wired)
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door closes to the CLOSE limit
Door opening Door stops and activates TTC
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Button is held (constant pressure)
Door opening No change in state (bypasses Mid-Stop) and activates TTC
myQ
®
Smart
Facility Access
Open is pressed
Operator at OPEN limit No change in state (Recycle timer)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Close is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit