DETERMINE AND SET OPERATING MODE (CONTINUED)
WIRING TYPE DEVICE ACTION STATE RESPONSE
TS
This mode will
attempt to close
the door from any
position
except when fully
closed, or when
a safety input is
present.
The stop button
will recycle the
Timer-To-Close
(TTC) at any
position. To disable
the TTC in this
mode, installation
of a defeat switch
is required (see
wiring diagram).
Momentary contact
to open, close, and
stop with open
override and TTC.
Every device that
causes door to
open, including a
reversing device,
activates the TTC.
Auxiliary controls
can be connected
to open input to
activate the TTC. If
the timer has been
activated, the open
button and radio
control can recycle
the timer. The TTC
will function from
the Open limit and
Open mid stop
(jumper must
always be in place)
with this operating
mode type.
Compatible with
3-Button Station,
1-Button Station
and 1 and 3-Button
Remote Control.
LiftMaster
Monitored
Entrapment
Protection (LMEP)
Device required.
Front panel
buttons(membrane)
and 3-Button
Control Station
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state (Recycle TTC)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed momentarily
Operator at OPEN limit No change in state (Recycle TTC)
Operator at CLOSE limit No change in state
Door opening Door stops and activates TTC
Door closing Door stops and activates TTC
Door at Open Mid-Stop No change in state (Recycle TTC)
Door stopped during open or close cycle No change in state (Recycle TTC)
OPEN button is held (constant
pressure)
Operator at OPEN limit No change in state (Recycle & hold TTC)
Operator at CLOSE limit Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC
Door opening No change in state (bypasses Mid-Stop) and activates TTC
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC
CLOSE button is held (constant
pressure)
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit No change in state (Recycle TTC)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
CLOSE button is pressed
momentarily
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit
STOP button is pressed momentarily
Operator at OPEN limit No change in state (Recycle TTC)
Operator at CLOSE limit No change in state
Door opening Door stops and activates TTC
Door closing Door stops and activates TTC
Door at Open Mid-Stop No change in state (Recycle TTC)
Door stopped during open or close cycle No change in state (Recycle TTC)
Single Button
Remote Control
Programmed as
SBC
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening Door stops and activates TTC
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Single Button
Control Station
(Wired)
Button is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC
Door opening Door stops and activates TTC
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Button is held (constant pressure)
Door opening No change in state (bypasses Mid-Stop) and activates TTC
myQ
®
Smart
Facility Access
Open is pressed
Operator at OPEN limit No change in state (Recycle TTC)
Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop (activates TTC)
Door opening No change in state
Door closing Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC
Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC
Close is pressed
Operator at OPEN limit Door closes to the CLOSE limit
Operator at CLOSE limit No change in state
Door opening No change in state
Door closing No change in state
Door at Open Mid-Stop Door closes to the CLOSE limit
Door stopped during open or close cycle Door closes to the CLOSE limit