Installation Manual

37
Error Code: Description: Level: Cause: Check:
F08 Configuration not found.
Reset to factory setting.
No stored configuration could be
fround in EEPROM. The access to
the EEPROM works. Normal for
instance with new controller, and/
or after certain tests with the test
system (production).
The stored configuration is oudated
and no longer compatible with the
current software. Can occur after an
update to a new version
F09 System was restarted
F10 UPWARD force curve is
missing
Force sensing in UPWARD direction is
activated. But force curve in UPWARD
direction is not stored. Execute teach-
in drive.
F11 DOWNWARD force curve is
missing
Force sensing in DOWNWARD
direction is activated. But force curve
in DOWNWARD direction is not stored.
Execute teach-in drive.
F14 End positions are not stored Please set the end positions in the
menu ‘Door Positions’.
F18 Error during access from
EEPROM module. Leads to
system restart.
Hardware error in I
2
C bus, or in
EEPROM
TROUBLESHOOTING
F23 Inverter reports excessive
temperature. Stands until
inverter cools down.
Temperature in inverter module
exceeds maximum value of 90°C
Inverter ready for operation, when
temperature sinks under 60°C
F24 Error during cyclical test of
the safety chain function
When the door is stationary, a test of
the safety chain is carried out every
10 seconds, in which the safety chain
switches, which is then scanned by a
command at the inverter.
Communication error
Error in the system of the safety
chain
F25 Inverter has reported a
hardware error
Inverter has detected an error when
analyzing the motor currents and
voltages.
One or more motor phases are not
connected
The motor phases are not
interconnected correctly
Hardware error in the measuring
bridges, on the side of the inverter.
overvoltage on the circuit board
(voltage too high in the link)
F72 OSE error OSE continously triggered, e.g. due
to cable defect or block in the light
channel
F74 Wireless (radio) OSE error
OSE continuously triggered
OSE test function fails
Cause depends on used OSE, e.g.
due to cable defect, block in the light
channel, battery OSE
F81 Light barrier error Light barrier continuously triggered, or
test cannot be executed
Object in door area
Cable defect
Light barrier incorrectly aligned
Light barrier incorrectly wired
Incorrect Hi/Lo setting