MODEL HP VOLTAGE PHASE AMPS POWER
(FT
LBS/
SEC)
HPH1
1.25 HP 120V 1
1.25 HP 240V 1
1.25 HP 230V 3
HPH2
1.25 HP 460V 3
1.25 HP 575V 3
TYPE: Limited Duty: up to 100 cycles per hour
up to 650 cycles per day
ELECTRICAL
DOOR IN MOTION RELAY: 1A @ 24Vdc OR 0.5A @ 120Vac
AUXILIARY OUTPUT VOLTAGE:
24Vdc ; 500mA
CONTROL STATION: VFD Controller with Integrated Open/
Close/Stop Controls, LCD Display, floor
level wiring, and floor level commissioning
through intuitive user menu.
OPERATING MODES: B2, C2, D1, E2, T, TS. FSTS. See page 29
for more information regarding operating
modes.
BRAKE: Solenoid powered-off brake standard on
all units
MANUAL HOIST: Single action manual hoist with integral
manual operation protection circuit.
CABLE TENSION MONITOR:
Detects ANY slack that may occur in the cables and will reverse
the door, eliminating service calls.
MECHANICAL
DRIVE REDUCTION:
1.25HP Operator: 20:1 High-Efficiency 2-Stage
Gearbox.
DOOR SPEED:
Three preconfigured frequency profiles.
LIMIT ADJUST:
Electronic limits, Floor level adjustability up to
20ft.
TEMPERATURE RATINGS: -20°C (14°F) to +40°C (104°F)
OPERATOR SPECIFICATIONS
VOLTAGE SELECTION
MODEL HP VOLTAGE PHASE
HPH1 1.25 120V 1 Phase
HPH1 1.25 240V 1 Phase
HPH1 1.25 230V 3 Phase
HPH2 1.25 460V 3 Phase (via separate stepdown transformer)
HPH2 1.25 575V 3 Phase (via separate stepdown transformer)
FOR SECTIONAL DOORS (SECTIONAL, HIGH-LIFT OR VERTICAL)
WEIGHT MAX. DOOR WEIGHT SPEED DRUM SIZE OUTPUT SHAFT SPEEDS
1025 lbs Avg. of 24"/sec
80 RPM - 60hz (big heavy doors)
120 RPM - 90hz (average doors)
160 RPM - 120 hz (small, light doors)
FOR ROLLING STEEL DOORS
WEIGHT MAX. DOOR WEIGHT SPEED DRUM SIZE OUTPUT SHAFT SPEEDS
500 lbs Avg. of 24"/sec
80 RPM - 60hz (big heavy doors)
120 RPM - 90hz (average doors)
160 RPM - 120 hz (small, light doors)
THIS DATA AND THE FOLLOWING PAGE MAY NOT BE ACCURATE OR IS PENDING.
PLEASE PROVIDE ACCURATE INFORMATION FOR THE HPH1