Installation Manual

40
Please note that the terminal block is numbered for easy identification.
Open – Membrane Button
Type: Normally-Open dry contact membrane switch with
tactile feedback
States:
Active input Definition: Connect Input to ground
Inactive input Definition: Leave input open (no connec-
tion to ground)
Close – Membrane Button
Type: Normally-Open dry contact membrane switch with
tactile feedback
States:
Active input Definition: Connect Input to ground
Inactive input Definition: Leave input open (no connec-
tion to ground)
Stop – Membrane Button
Type: Monitored Normally-Open dry contact membrane
switch with tactile feedback
States:
Active input Definition: Connect Input to ground
Inactive input Definition: Input left open (resistor voltage
measured)
Missing input Definition: Input not connected (full voltage
measured)
PROGRAMMABLE INPUTS
AUX1 and AUX2 inputs are user selectable and may be
defined as the following:
No Function (default)
Function - Input is disabled
Emergency Stop
Function – Active input will stop a door in motion
and will inhibit an idle door from moving.
Photoeye
Function – Safety entrapment protection, non-moni-
tored, see section 4.3
Lock Open
Function - Active input disables all command inputs
except Open. Door can open but once at open limit,
door is prevented from closing. Inhibits Timer to
Close and Delay to Close.
Lock Close
Function - Active input disables all command inputs
except Close. Door can close but once at closed
limit, door is prevented from opening.
Grounds
Terminal
Number
Input
Name
Default Function
#2 0V Ground
#4 0V Ground
#10 0V Ground
#20 0V Ground
#23 0V Ground
#28 0V LMEP Ground
#32 0V Ground for Encoder
#34 0V Ground
Inputs
Terminal
Number
Input
Name
Default Function
#1 Safety
Edge
Safety Edge (Non-monitored)
#3 Analog
Input
Not used
#6 RPM Not used
#7 OMS Mid-Stop Input
#8 AUX1 Programmable Input
#9 AUX2 Programmable Input
#11 Open Door Open Input
#12 Close Door Close Input
#13 Stop Door Stop Input
#14 SBC Single Button Close Input
#15 TDFT Timer Defeat Input
#17 Hoist Chain Hoist Chain Input
#19 N/C Not Used
#21 Thermal Motor Thermal Input
#24 NO Door in Motion Relay: Normally
Open
#25 COM Door in Motion Relay:
Common
#26 NC Door in Motion Relay: Normally
Closed
#27 LMEP Monitored Photo Eye
#30 A Encoder RS-485 A
#31 B Encoder RS-485 B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
SBC
27 28 29 30 31 32 33 34
Borde de
seguridad
LMEP
LMEP
tierra
12V
(Codificador)
Codificador A
Codificador B
Codificador
tierra
+24V
Tierra
Entrada
analógica
0V
+24V
RPM
OMS
AUX1
0V
AUX2
0V
APERTURA
CIERRE
PARADA
TDFT
+24V
Cadena de
polispasto
+24V
probado
No
utilizado
0V
Térmica
+24V
0V
NO
COM
NC
WIRING DIAGRAMS
Hoist Interlock
(not provided)
FRONT COVER OF WALL CONTROL
Power
Terminal
Number
Input
Name
Default Function
#5 +24V Aux Power
#16 +24V Aux Power
#18 +24V_Tested Not Used
#22 +24V Aux Power
#29 12V 12V Power for Encoder
#33 +24V Aux Power
* Terminals in gray can be found on the top board of the wall control.