User Manual

3
LiftMaster
NOTE: The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic
Programming, page 2.
KPW5 - The frequency and encryption are set at the factory. Proceed to Step 4.
KPW250 - The frequency and encryption are set at the factory for LiftMaster Security+ 2.0 (tri-band 310,
315, and 390 MHz) operators. Proceed to Step 4.
For LiftMaster Security+ (315 MHz or 390 MHz), the frequency and encryption need to be set.
Proceed to Step 1.
1. Enter program mode:
*
(Master Code) #
2 Set frequency and encryption (KPW250 only):
LiftMaster Security+ 315 MHz - Press 03 # 2 #. A long tone will sound.
LiftMaster Security+ 390 MHz - Press 03 # 3 #. A long tone will sound.
To reset factory default - Press 03 # 1 #. A long tone will sound.
3. Exit Program Mode:
*
*
#.
4. Press the Learn Button on the operator.
5. Within 30 seconds- Enter a valid 4-digit PIN then press #. A long tone will sound.
PROGRAM TO OPERATOR
Linear Multi-Code
KPW250 ONLY
1. Locate the DIP switch sequence on the operator and record it. If DIP switch is in the “up” or “on” (CLOSED)
position place a 1, “down” or “off” (OPEN) position place a 0 in the corresponding box in the chart below.
NOTE: Leave any unused switch locations blank.
Write the DIP switch 10-digit sequence: ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
2. Enter program mode:
*
(Master Code) #. A long tone will sound.
3. Set Linear Multi-Code frequency and encryption: Press 03 # 4 #. A long tone will sound.
4. Enter the DIP Switch sequence (Use ONLY 1 and 0). Press #. A long tone will sound.
3. Exit Program Mode:
*
*
#.
NOTE: When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is input.
DIP Switch Sequence 1 2 3 4 5 6 7 8 9 10
UP / ON (CLOSED)
DOWN / OFF (OPEN)
Once an operator has been programmed, enter a valid 4-digit PIN and the # key to activate the operator.