Users Manual Part 3

17
Step 6 Connect Batteries
7AH Batteries
The batteries are charged in the circuit by the integrated transformer.
1. Turn the AC power switch to OFF.
2. Turn the battery switch OFF .
3. Connect a jumper between the positive(+) terminal of the battery to
the negative terminal(-) of the other battery.
4. Connect the red battery wire from the operator to the positive(+)
terminal of the battery.
5. Connect the black battery wire from the operator to the negative (-)
terminal of the battery.
6. Turn the battery switch ON .
7. Turn the AC power switch to ON to restore AC power.
Battery Wiring
Red Wire
Black Wire
Jumper
33AH Batteries
The batteries are charged in the circuit by the integrated transformer.
The 33AH application requires battery harness K41-0102-000, see
Accessories.
1. Turn the AC power switch to OFF.
2. Turn the battery switch OFF.
3. Connect a jumper between the positive(+) terminal of the battery to
the negative terminal(-) of the other battery.
4. Connect the (+) terminal of the battery to the red battery wire from
the operator using the RED harness kit wire .
5. Connect the (-) terminal of the battery to the black battery wire from
the operator using the BLACK harness kit wire.
6. Turn the battery switch ON .
7. Turn the AC power switch to ON to restore AC power.
Battery Wiring
Red Wire
Black Wire
Jumper (White Wire)
from K41-0102-000
Red wire from
battery harness
33AH, HD Gates
K41-0102-000
Black wire
from battery
harness 33AH,
HD Gates
K41-0102-000
INSTALLATION

Summary of content (6 pages)