Users Manual Part 5

25
LiftMaster Internet Gateway
(notprovided)
To program the operator to the LiftMaster Internet Gateway:
1. Connect the ethernet cable to the LiftMaster Internet Gateway and the
router.
2. Connect power to the LiftMaster Internet Gateway.
3. Download the myQ
®
App.
4. Set up an account and follow the app instructions to add your gate
operator.
5. The LiftMaster Internet Gateway will pair to the operator if it is within
range and the operator will beep if programming is successful.
The gate operator can then be controlled through the myQ
®
App.
To erase the gateway:
1. Press and release the LEARN button on either operator. The green
XMITTER LED will light.
2. Press and release the LEARN button again on the same operator. The
yellow NETWORK LED will light.
3. Press and hold the LEARN button for 5 seconds. The yellow
NETWORK LED will blink (operator will beep) then turn off indicating
devices have been successfully erased.
CAPXLV Connected Access Portal
The CAPXLV can communicate wirelessly to LiftMaster
®
UL325 2016 gate
operators to send open commands, monitor gate position, and send email
notifications if an error occurs in the operator (email notifications are
configured in myQ
®
Business™). Up to 8 gate operators can be paired with
the CAPXLV - one for each primary and auxiliary relay. If using dual gates,
program the CAPXLV to the primary operator.
To Program the CAPXLV:
1. Enter Admin Mode - Flip dipswitch #1 to the ON position to enter
Admin Mode. NOTE: For new installations press the login button
without entering information in the Admin Username and Admin
Password fields.
CAPXLV
ON
ON
2. Select Outputs and Relay - Select the Outputs tab. Then select the
desired relay on the left-hand side (1 through 4).
3. Press LEARN button on gate operator - Press and release the LEARN
button on the primary operator. The green XMITTER LED will light.
NOTE: The operator will time out of programming mode after 180
seconds.
4. Press LEARN button on gate operator again - Press and release the
LEARN button again on the primary operator. The yellow NETWORK
LED will light.
5. Select LEARN on display - Select the LEARN button on the display and
the Learn button will go from blue to red. The gate operator and the
CAPXL will beep once and the NETWORK LED on the gate operator will
turn off indicating programming is successful. NOTE: 4 beeps/blinks
indicate you are not programming to the primary operator. Reattempt
programming from the other operator.
PROGRAMMING

Summary of content (5 pages)