Installation Guide
Table Of Contents
- ENGLISH
- BILT Intelligent Instructions
- Installation Manual
- Contents
- Safety Symbol and Signal Word Review
- Preparation
- Assembly
- Installation
- STEP 1 Determine the Header Bracket Location
- STEP 2 Install the Header Bracket
- STEP 3 Attach the Rail to the Header Bracket
- STEP 4 Position the Garage Door Opener
- STEP 5 Hang the Garage Door Opener
- STEP 6 Install the Light Bulbs
- STEP 7 Attach the Emergency Release Rope and Handle
- STEP 8 Install the Door Bracket
- STEP 9 Connect the Door Arm to the Trolley
- STEP 10 Install the Door Control
- STEP 11 Wire the Door Control to the Garage Door Opener
- STEP 12 Attach the Warning Labels
- STEP 13 Install the Protector System®
- STEP 14 Wire the Safety Reversing Sensors
- STEP 15 Connect Power
- STEP 16 Align the Safety Reversing Sensors
- Adjustments
- Battery Backup
- myQ® App Control
- Operation
- Maintenance
- Troubleshooting
- Warranty
- Contact Information
- Automatic Garage Door Opener Safety & Maintenance Guide
- Repair Parts
30
Installation
STEP 14 Wire the Safety Reversing Sensors (continued)
OPTION B - PRE-WIRED INSTALLATION
1. Cut the sensor wires, making sure there is enough wire to reach the pre-installed wires from the wall.
2. Separate the sensor wires and strip insulation from each end. Choose two of the pre-installed wires
and strip insulation from each end. Choose the same color pre-installed wires for each sensor.
3. Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond
for each sensor.
4. At the garage door opener, strip the end of the wires previously connected to the sensors. Twist the
like-colored wires together.
5. Using a screwdriver, push in the terminal tabs, and insert the wire color connected to the sensor's
white wire into the white terminal. Insert the other wire color connected to the sensor's white/black wire
into the grey terminal.
Safety reversing sensor wires
White
White/Black
Yellow (for example)
Purple (for example)
Wire nuts (not provided)
Pre-installed wires
Safety reversing
sensor wires
1
3
4
7/16" (11 mm)
2
5
Purple
Yellow
Pre-installed
wires
Pre-installed wires
7/16" (11 mm)
Yellow
Purple
Wire channel