Replacement Part List
Table Of Contents
- ENGLISH
- Contents
- Safety Symbol and Signal Word Review
- Preparation
- Assembly
- Installation
- STEP 1 Determine the Header Bracket Location
- STEP 2 Install the Header Bracket
- STEP 3 Attach the Rail to the Header Bracket
- STEP 4 Position the Garage Door Opener
- STEP 5 Hang the Garage Door Opener
- STEP 6 Attach the Emergency Release Rope and Handle
- STEP 7 Install the Door Bracket
- STEP 8 Connect the Door Arm to the Trolley
- STEP 9 Install the Door Control
- STEP 10 Wire the Door Control to the Garage Door Opener
- STEP 11 Attach the Warning Labels
- STEP 12 Install the Protector System®
- STEP 13 Wire the Safety Reversing Sensors
- STEP 14 Connect Power
- STEP 15 Align the Safety Reversing Sensors
- Adjustments
- Battery Backup
- myQ® App Control
- Camera
- Operation
- Maintenance
- Troubleshooting
- Warranty
- Automatic Garage Door Opener Safety & Maintenance Guide
- Repair Parts
28
1
3
Staple
HARDWARE
Insulated Staple (Not Shown)
2
7/16” (11 mm)
Wire channel
Installation
STEP 13 Wire the Safety Reversing Sensors
If your garage has pre-installed wiring for the safety reversing sensors, see OPTION B- PRE-WIRED
INSTALLATION page 27.
OPTION A- INSTALLATION WITH NO PRE-WIRING
1. Run the wire from both sensors to the garage door opener. Attach with staples, but DO NOT
puncture the wire.
2. Separate the sensor wires and strip insulation from each end. Twist the two white wires together.
Then twist the two white/black wires together.
3. Using a screwdriver, push in the terminal tabs, and insert the white wires into the white terminal.
Insert the white/black wires into the grey terminal.