Replacement Part List

Table Of Contents
31
Light Beam Protection Area
Wing nut
1
2
3
Installation
STEP 15 Align the Safety Reversing Sensors
IMPORTANT: The safety reversing sensors MUST be connected and aligned correctly before
the garage door opener will move in the down direction.
When the garaged door opener has power, check the safety reversing sensors. If the sensors are aligned and wired
correctly, both LEDs will glow steadily.
Sending sensor - amber LED Receiving sensor - green LED
To align the safety reversing sensors:
1. Loosen the wing nuts.
2. Adjust the sensors up or down until both LEDs glow steady indicating alignment.
3. Tighten the wing nut to secure the sensor.
SAFETY SENSOR TROUBLESHOOTING
IfeitherofthesensorLEDsareo,thereisnopowertothesensor:
1. Check that you have power to the garage door opener.
2. Check the sensor wire is not shorted or broken.
3. Check that the sensors is wired correctly; white wires to white terminal and white/black wires to
grey terminal.
RED
IfthegreenreceivingsensorLEDisblinking,thesensorsareobstructedormisaligned:
1. Check for obstructions in the sensor light beam.
2. Align the sensors.
3. If the receiving sensor (green LED) faces direct sunlight, switch the receiving sensor with the
sending sensor and repeat STEP 12 Install the Protector System® page 26 to assure proper
operation.
WHITE
GREY
STEP 16 Ensure the Door Control is Wired Correctly
If the door control has been installed and wired correctly, the command LED on the Motion-Detecting Control
Panel will blink.