Replacement Part List
Table Of Contents
- ENGLISH
- Contents
- Safety Symbol and Signal Word Review
- Preparation
- Assembly
- Installation
- STEP 1 Determine the Header Bracket Location
- STEP 2 Install the Header Bracket
- STEP 3 Attach the Rail to the Header Bracket
- STEP 4 Position the Garage Door Opener
- STEP 5 Hang the Garage Door Opener
- STEP 6 Attach the Emergency Release Rope and Handle
- STEP 7 Install the Door Bracket
- STEP 8 Connect the Door Arm to the Trolley
- STEP 9 Install the Door Control
- STEP 10 Wire the Door Control to the Garage Door Opener
- STEP 11 Attach the Warning Labels
- STEP 12 Install the Protector System®
- STEP 13 Wire the Safety Reversing Sensors
- STEP 14 Connect Power
- STEP 15 Align the Safety Reversing Sensors
- Adjustments
- Battery Backup
- myQ® App Control
- Camera
- Operation
- Maintenance
- Troubleshooting
- Warranty
- Automatic Garage Door Opener Safety & Maintenance Guide
- Repair Parts
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY
INJURED or KILLED by a closing garage door.
l Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal
system.
l After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on
contact with 1-1/2” (3.8 cm) high object (or 2x4 laid at) on oor.
While programming the travel, the UP and DOWN buttons can be used to move the door as needed. The Safety
Reversing Sensors will be disconnected during the Program the Travel process. During the Automatic Force
Setup the door will automatically open and close.
1 Press and hold the Adjustment
Button until the UP Button begins to
ash and/or a beep is heard.
The Safety Reversing Sensors will be
disconnected during the Program the
Travel process.
3 Once the door is in the desired
UP position press and release the
Adjustment Button. The garage door
opener lights will ash twice and the
DOWN Button will begin to ash.
2 Press and hold the UP
Button until the door is in
the desired UP position.
5 Once the door is in the desired DOWN position press and
release the Adjustment Button. The garage door opener
lights will ash twice. Program the Travel is now complete.
If the garage door opener lights ash 5 times, then
programming has timed out and the Travel Limits have not
been set. Please restart the Program the Travel process.
4 Press and hold the
DOWN button until the
door is in the desired
DOWN position.
33
Adjustment
1- Program the Travel
2 - Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety Reversing Sensors will reconnect and
become operational. Then, the opener will enter a force-sensing operation by automatically moving the door
open and close. The garage door opener will sound an audible and visual alert before automatically opening
and closing the door. The garage door opener will beep three times, conrming that the Automatic Force Setup
completed successfully. Adjustment is complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set Up has not completed
successfully. Please start over at step 1 of Program the Travel.