Installation Manual
Table Of Contents
- Preparation
- Assembly
- Installation
- STEP 1 Determine the header bracket location
- STEP 2 Install the header bracket
- STEP 3 Attach the rail to the header bracket
- STEP 4 Position the garage door opener
- STEP 5 Hang the garage door opener
- STEP 6 Install the Light Bulbs
- STEP 7 Attach the emergency release rope and handle
- STEP 8 Install the door bracket
- STEP 9 Connect the door arm to the trolley
- STEP 10 Install the door control
- STEP 11 Wire the door control to the garage door opener
- STEP 12 Attach the warning labels
- STEP 13 Install the Protector System®
- STEP 14 Wire the Safety Reversing Sensors
- STEP 15 Connect power
- STEP 16 Aligning the safety reversing sensors
- STEP 17 Ensure the door control is wired correctly
- Adjustments
- MyQ® Smartphone Control
- Operation
- Maintenance
- Troubleshooting
- Accessories
- Warranty
- Contact Information
- Repair Parts
22
Installation
STEP 11 Wire the door control to the garage door opener
1. Run the white and red/white wire from the door control to the garage door opener. Attach the wire to the
wall and ceiling with the staple (not applicable for gang box or pre-wired installations). Do not pierce the
wire with the staple as this may cause a short or an open circuit.
2. Strip 7/16 inch (11 mm) of insulation from the end of the wire near the garage door opener.
3. Connect the wire to the red and white terminals on the garage door opener. If your garage is pre-wired
make sure you use the same wires that are connected to the door control. To insert or release wires from
the terminal, push in the tab with screwdriver tip.
RED
WHITE
WHITE
GREY
7/16" (11 mm)
2
3
1
HARDWARE
Insulated Staple (Not Shown)
Staple
STEP 12 Attach the warning labels
1. Attach the entrapment warning label on the wall near the door control with tacks or staples.
2. Attach the manual release/safety reverse test label in a visible location on the inside of the garage door.