Installation Manual
Table Of Contents
- Preparation
- Assembly
- Installation
- STEP 1 Determine the header bracket location
- STEP 2 Install the header bracket
- STEP 3 Attach the rail to the header bracket
- STEP 4 Position the garage door opener
- STEP 5 Hang the garage door opener
- STEP 6 Install the Light Bulbs
- STEP 7 Attach the emergency release rope and handle
- STEP 8 Install the door bracket
- STEP 9 Connect the door arm to the trolley
- STEP 10 Install the door control
- STEP 11 Wire the door control to the garage door opener
- STEP 12 Attach the warning labels
- STEP 13 Install the Protector System®
- STEP 14 Wire the Safety Reversing Sensors
- STEP 15 Connect power
- STEP 16 Aligning the safety reversing sensors
- STEP 17 Ensure the door control is wired correctly
- Adjustments
- MyQ® Smartphone Control
- Operation
- Maintenance
- Troubleshooting
- Accessories
- Warranty
- Contact Information
- Repair Parts
25
Installation
STEP 14 Wire the Safety Reversing Sensors
If your garage already has wires installed for the safety reversing sensors, proceed to page 26.
OPTION A - INSTALLATION WITHOUT PRE-WIRING
1. Run the wire from both sensors to the garage door opener. Attach the wire to the wall and ceiling with the
staples.
2. Strip 7/16 inch (11 mm) of insulation from each set of wires. Separate the wires. Twist the white wires
together. Twist the white/black wires together.
3. Insert the white wires into the white terminal on the garage door opener. Insert the white/black wires into
the grey terminal on the garage door opener. To insert or remove the wires from the terminal, push in the
tab with a screwdriver tip.
Staple
7/16" (11 mm)
WHITE
WHITE
GREY
RED
1
2
3
HARDWARE
Insulated Staple (Not Shown)