The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.chamberlain.com GARAGE DOOR OPENER Models • CG40CD 1/2 HP • CG42CD 1/2 HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation. ■ The door WILL NOT CLOSE unless The Protector System® is connected and properly aligned. ■ Periodic checks of the opener are required to ensure safe operation.
TABLE OF CONTENTS Introduction 2-7 Adjustment Safety symbol and signal word review........................2 Preparing your garage door ........................................3 Tools needed ...............................................................3 Planning ..................................................................4-5 Carton inventory ..........................................................6 Hardware inventory .....................................................
Preparing your garage door WARNING Before you begin: • Disable locks. • Remove any ropes connected to garage door. • Complete the following test to make sure your garage door is balanced and is not sticking or binding: 1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs. 2. Raise and lower the door to see if there is any binding or sticking.
Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. Depending on your requirements, there are several installation steps which may call for materials or hardware not included in the carton.
Planning (Continued) WARNING ONE-PIECE DOOR INSTALLATIONS • Generally, a one-piece door does not require reinforcement. If your door is lightweight, refer to the information relating to sectional doors in Installation Step 11. • Depending on your door’s construction, you may need additional mounting hardware for the door bracket (Step 11). Without a properly working safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
Carton Inventory Hardware for assembly and installation is shown on the next page. Save the carton and packing material until installation and adjustment is complete. Your garage door opener is packaged in one carton which contains the motor unit and all parts illustrated below. Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures.
WARNING CAUTION ASSEMBLY STEP 1 Assemble the Rail & Install the Trolley To prevent INJURY from pinching, keep hands and fingers away from the joints while assembling the rail. To avoid installation difficulties, do not run the garage door opener until instructed to do so. 3. Place the motor unit on packing material to protect the cover, and rest the back end of the rail on top. For convenience, put a support under the front end of the rail. 4.
WARNING ASSEMBLY STEP 2 CAUTION Fasten the Rail to the Motor Unit To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners mounted in the top of the opener. • Insert a 1/4"-20x1-3/4 bolt into the cover protection bolt hole on the back end of the rail as shown. Tighten securely with a 1/4"-20 lock nut. Do NOT overtighten. • Remove the two bolts from the top of the motor unit. • Place the “U” bracket, flat side down onto the motor unit and align the bracket hole with the bolt holes.
WARNING ASSEMBLY STEP 4 Install the Chain/Cable 1. Pull the cable around the idler pulley and toward the trolley. 2. Connect the cable to the retaining slot on the trolley, as shown (Figure 1): • From below, push pins of master link bar up through cable link and trolley slot. • Push master link cap over pins and past pin notches. • Slide clip-on spring over cap and onto pin notches until both pins are securely locked in place. 3.
ASSEMBLY STEP 5 Tighten the Chain Figure 1 • Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley. • To tighten the chain, turn outer nut in the direction shown (Figure 1). • When the chain is approximately 1/4" (6 mm) above the base of the rail at its midpoint, re-tighten the inner nut to secure the adjustment. Sprocket noise can result if chain is too loose. When installation is complete, you may notice some chain droop with the door closed. This is normal.
Unfinished Ceiling INSTALLATION STEP 1 OPTIONAL CEILING MOUNT FOR HEADER BRACKET Determine the Header Bracket Location Header Wall WARNING 2x4 Vertical Centerline of Garage Door To prevent possible SERIOUS INJURY or DEATH: • Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might not reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
INSTALLATION STEP 2 Wall Mount Install the Header Bracket You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).
INSTALLATION STEP 3 Attach the Rail to the Header Bracket NOTE: (Optional) With some existing installations, you may re-use the old header bracket with the two plastic spacers included in the hardware bag. Place the spacers inside the bracket on each side of the rail, as illustrated. • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help.
WARNING CAUTION INSTALLATION STEP 4 Position the Opener To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door. Follow instructions which apply to your door type as illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
WARNING INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing any brackets into masonry. Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener.
WARNING INSTALLATION STEP 6 Install the Door Control To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is not connected BEFORE installing door control. • Connect ONLY to 24 VOLT low voltage wires. To prevent possible SERIOUS INJURY or DEATH from a closing garage door: • Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from all moving parts of door.
WARNING CAUTION INSTALLATION STEP 7 Install the Light and Lens To prevent possible OVERHEATING of the endpanel or light socket, • DO NOT use short neck or specialty light bulbs. • DO NOT use halogen bulbs. Use ONLY incandescent. INSTALL THE LIGHT • Install a 75 watt maximum light bulb in the socket. The light will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the light will turn OFF. • Use standard neck Garage Door Opener bulbs for replacement.
INSTALLATION WARNING STEP 9 WARNING Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: • Be sure power is not connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with all local electrical and building codes. • NEVER use an extension cord, 2-wire adapter, or change plug in any way to make it fit outlet. Be sure the opener is grounded.
WARNING INSTALLATION STEP 10 Install The Protector System ® Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from a closing garage door: • Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled. • nstall the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows. Figure 1 DOOR TRACK MOUNT (RIGHT SIDE) Door Track Lip Indicator Light Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door.
MOUNTING AND WIRING THE SAFETY SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5). • Finger tighten the wing nuts. • Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling. • Strip 1/4" (6 mm) of insulation from each set of wires.
WARNING CAUTION INSTALLATION STEP 11 Fasten the Door Bracket Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes. • Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
INSTALLATION STEP 12 Pulley Connect Door Arm to Trolley 8" (20 cm) min. Follow instructions which apply to your door type as illustrated below and on the following page. Trolley Stop Bolt SECTIONAL DOORS ONLY • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the pulley) about 8" (20 cm) as shown in Figures 1, 2 and 3.
ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin. • Secure with a ring fastener. 2. Adjustment procedures, Figure 5: • On one-piece doors, before connecting the door arm to the trolley, the travel limits must be adjusted.
WARNING ADJUSTMENT STEP 1 Adjust the UP and DOWN Travel Limits Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested.
WARNING ADJUSTMENT STEP 2 Adjust the Force Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Too much force on garage door will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close garage door. • NEVER use force adjustments to compensate for a binding or sticking garage door.
WARNING ADJUSTMENT STEP 3 Test the Safety Reversal System Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.
WARNING OPERATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel. 4. ALWAYS keep garage door in sight until completely closed.
Using the Wall-Mounted Door Control To Open the Door Manually WARNING Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening. To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
THE REMOTE CONTROL BATTERY CARE OF YOUR OPENER WARNING LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes INCREASE TRAVEL in door operation requiring DOWN UP some re-adjustments, LIMIT CONTROLS particularly during the first (Left panel) year of operation. Pages 27 and 28 refer to the limit and force adjustments. Only a screwdriver is Kg Kg required. Follow the FORCE CONTROLS (Back panel) instructions carefully.
HAVING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • Verify the safety sensors are properly installed, aligned and free of any obstructions. Refer to Installation Step 10: Install The Protector System®. • Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page.
Bell Wire Diagnostics Located On Motor Unit 1 2 Installed Safety Sensor 3 9 1 7 3 9 1 7 3 5 5 KG KG 1 "Learn" Button Safety Sensor LED or Diagnostic LED Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below. Diagnostic Chart 1 FLASH Safety sensors wire open (broken or disconnected).
PROGRAMMING NOTICE: If this Security✚® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON To change an existing, known PIN 1 2 9 1 7 1 1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds. If the existing PIN is known, it may be changed by one person without using a ladder. 1. Press the four buttons for the present PIN, then press and hold the # button.
REPAIR PARTS Rail Assembly Parts 2 1 3 4 5 6 KEY NO. PART NO. 1 2 3 4 5 6 4A1008 41C5141-1 41A5665-2 144C56 41A5807 12D598-1 183A163 DESCRIPTION Master link kit Complete trolley assembly Complete rail Idler pulley Chain and cable “U” bracket NOT SHOWN Wear pads Installation Parts 4 1 2 3 6 5 NOT KEY PART NO. NO.
Motor Unit Assembly Parts 1 2 20 4 3 8 16 19 17 18 16 13 15 9 10 3 6 5 7 11 LIMIT SWITCH ASSEMBLY (Down) Contact 14 Brown Wire Grey Wire DN UP Drive Gear Center Limit Contact 12 KEY NO. PART NO. 1 2 41A5615 41C4220A 3 41A2817 4 5 6 7 8 9 10 11 41B4245 143D100 175B88 108D36 30B532 12A373 41A3150 41D3058 KEY PART NO. NO. DESCRIPTION Chain Spreader Gear and sprocket assembly.
ACCESSORIES 953CD 3-Button SECURITY✚® Remote Control: Includes visor clip. 956CD 3-Button Mini-Remote Control with SECURITY✚®: With key ring and fastening strip. 940CD SECURITY✚® Keyless Entry: Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries.
CHAMBERLAIN SERVICE IS ON CALL ® OUR LARGE SERVICE ORGANIZATION SPANS AMERICA AND CANADA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SEVEN DAYS A WEEK. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-654-4736 HOURS: (Central Std. Time) 6:00 A.M. TO 7:00 P.M. - Monday through Friday 8:00 A.M. TO 6:00 P.M. - Saturday 8:00 A.M. TO 4:30 P.M. - Sunday www.chamberlain-diy.
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.chamberlain.com OUVRE-PORTE DE GARAGE Modèles • CG40CD 1/2 HP • CG42CD 1/2 HP Pour Résidences Seulement Manuel d’instructions ■ Lire attentivement ce manuel ainsi que les consignes de sécurité! ■ Après la pose, accrocher ce manuel près de la porte de garage pour s’y reporter ultérieurement. ■ La porte NE SE FERMERA PAS si Le Système Protector® n’est pas branché et réglé correctement.
TABLE DES MATIÈRES Introduction 2-7 Réglages Revue des symboles de sécurité et des mots de signalement ....................................................................2 Préparation de votre porte de garage .................................3 Outils nécessaires ...............................................................3 Planification .....................................................................4-5 Inventaire de la boîte d’emballage ......................................
AVERTISSEMENT Préparation de votre porte de garage AVERTISSEMENT Avant de commencer : • Désactiver les serrures. • Retirer toute corde raccordée à la porte de garage. • Réaliser le test suivant pour s’assurer que la porte de garage est équilibrée et qu’elle ne force pas : 1. Soulever la porte à moitié, comme illustré, puis la relâcher. Si elle est équilibrée, elle devrait rester en place, entièrement supportée par ses ressorts. 2. Faire monter et descendre la porte pour s’assurer qu’elle ne force pas.
Planification Identifier le type et la hauteur de votre porte de garage. Examiner la région du garage pour noter si l’une des conditions ci-après s’applique à votre installation. Des matériaux supplémentaires peuvent être nécessaires. Il vous sera peut-être utile de vous reporter à cette page et aux illustrations qui l’accompagnent en procédant à la pose de l’ouvre-porte.
AVERTISSEMENT Planification (Suite) AVERTISSEMENT POSE DE PORTE RIGIDE • En règle générale, une porte rigide ne nécessite aucun renfort. Pour une porte légère, prière de se reporter aux informations ayant trait aux portes articulées à la 11e opération de pose. • En fonction de la construction de la porte, des fixations supplémentaires seront peut-être requises pour le support de la porte (11e opération).
Inventaire de la boîte d’emballage Votre ouvre-porte de garage est emballé dans un boîte qui contiennent le moteur et les pièces illustrées ci-après. Les accessoires dépendront du modèle acheté. S’il manque quoi que ce soit, vérifier le matériel d’emballage. Les pièces peuvent être coincées dans la mousse. Les fixations nécessaires au montage et à la pose apparaissent sur la page suivante. Conserver la boîte et le matériel d’emballage jusqu’au terme de la pose et du réglage.
Inventaire des fixations Séparer toutes les fixations et les regrouper comme illustré ci-après aux fins des opérations de montage et de pose.
AVERTISSEMENT ATTENTION MONTAGE - 1re OPÉRATION Montage du rail et pose du chariot Afin de prévenir une BLESSURE occasionnée par un pincement, tenir les mains et les doigts loin des joints lors de l’assemblage du rail. Pour éviter les difficultés pendant la pose, ne faire fonctionner l'ouvre-porte de garage que lorsque cela est expressément indiqué. Le rail avant a une « fenêtre » découpée à l’extrémité porte (voir illustration).
AVERTISSEMENT ATTENTION MONTAGE - 2e OPÉRATION Fixation du rail au moteur Afin d’éviter d’endommager SÉRIEUSEMENT l’ouvre-porte de garage, utiliser UNIQUEMENT les boulons et les fixations montés sur le dessus de l’ouvre-porte. • Insérer un boulon de 1/4 po-20 x 1-3/4 dans le trou du boulon de protection du couvercle à l’extrémité arrière du rail, comme illustré. Serrer fermement à l’aide d’un contre-écrou de 1/4 po-20. Ne PAS trop serrer. • Retirer les deux boulons depuis le dessus de l’ouvre-porte.
AVERTISSEMENT AVERTISSEMENT MONTAGE - 4e OPÉRATION Pose de la chaîne et du câble 1. Tirer le câble autour de la poulie et vers le chariot. 2. Raccorder la boucle de câble à la fente de retenue sur le chariot, comme illustré (Figure 1) : • Depuis le dessous, pousser les chevilles de la barre du maillon de raccord vers le haut à travers la boucle de câble et la fente du chariot. • Pousser le chapeau du maillon de raccord par-dessus les chevilles et au-delà des encoches de cheville.
MONTAGE - 5e OPÉRATION Tension de la chaîne Figure 1 • Dévisser l’écrou intérieur de la tige filetée du chariot et éloigner la rondelle. • Pour tendre la chaîne, tourner l’écrou extérieur dans le sens illustré (Figure 1). • Lorsque la chaîne est à environ 1/4 po (6 mm) au-dessus du patin du rail en son point milieu, resserrer l’écrou intérieur pour garder le réglage. Le pignon peut faire du bruit si la chaîne est trop détendue. Lorsque la pose est terminée, la chaîne peut pendre lorsque la porte est fermée.
POSE – 1re OPÉRATION AVERTISSEMENT MONTAGE DU SUPPORT DE LINTEAU AU PLANFOND EN OPTION Plafond non fini Déterminer l’emplacement du support de linteau AVERTISSEMENT 2x4 Linteau Ligne du centre vertical de la porte de garage Pour prévenir d’éventuelles BLESSURES GRAVES ou LA MORT : • Le support de linteau DOIT être fixé DE MANIÈRE RIGIDE à la solive sur le linteau ou le plafond, sinon la porte de garage pourrait ne pas remonter au besoin.
Montage mural POSE - 2e OPÉRATION Pose du support de linteau Le support de linteau peut être fixé soit sur le mur, au-dessus de la porte, soit sur le plafond. Suivre les instructions qui répondent le mieux aux besoins particuliers. Ne pas poser le support de linteau sur des plaques de placoplâtre. Utiliser des ancrages de béton (non fournis) pour la pose dans la maçonnerie.
POSE - 3e OPÉRATION Fixation du rail sur le support de linteau REMARQUE : (Facultatif) Pour certaines installations préexistantes, il est possible de réutiliser l’ancien support de linteau avec les deux entretoises en plastique comprises dans le sac de quincaillerie. Placer les entretoises à l’intérieur du support de chaque côté du rail, comme illustré. • Positionner l'ouvre-porte de garage sur le plancher, juste sous le support de linteau. Utiliser une des boîtes d'emballage pour le protéger.
AVERTISSEMENT ATTENTION POSE - 4e OPÉRATION Positionnement de l'ouvre-porte Pour prévenir les dommages à la porte de garage, faire reposer le rail de l’ouvre-porte de garage sur un 2 x 4 placé sur la section supérieure de la porte. Suivre les instructions qui se rapportent à la porte de garage particulière, en se rapportant aux illustrations. PORTE ARTICULÉE OU PORTE RIGIDE AVEC GUIDES Un 2 x 4 posé à plat convient très bien pour obtenir l'espace qu'il faut entre la porte et le rail.
AVERTISSEMENT AVERTISSEMENT POSE - 5e OPÉRATION Accrochage de l'ouvre-porte Pour éviter d’éventuelles BLESSURES GRAVES par suite de la chute d’un ouvre-porte de garage, fixer l’ouvre-porte SOLIDEMENT aux solives du garage. On DOIT utiliser des ancrages de béton si les supports sont posés dans la maçonnerie. Les illustrations représentent trois poses types. La pose peut toutefois être différente. Les supports de suspension doivent être inclinés, (Figure 1) pour assurer un support rigide.
AVERTISSEMENT POSE - 6e OPÉRATION Pose de la Commande de Porte Pour prévenir d’éventuelles BLESSURES GRAVES ou la MORT par suite d’électrocution : • S’assurer que le courant est coupé AVANT de poser la commande de porte. • Raccorder UNIQUEMENT à des fils basse tension 24 V.
AVERTISSEMENT ATTENTION POSE - 7e OPÉRATION Pose de l’ampoule et de diffuseur Pour éviter toute SURCHAUFFE éventuelle du panneau d’éclairage, • NE PAS utiliser d’ampoules à col court ou de forme spéciale. • NE PAS utiliser d’ampoules halogène. Utiliser UNIQUEMENT des ampoules incandescentes. • Visser une ampoule de 75 watts maximum dans chaque douille. Le ampoule s'allumeront et resteront allumées pendant environ 4-1/2 minutes aussitôt que le courant sera établi.
AVERTISSEMENT POSE - 9e OPÉRATION AVERTISSEMENT AVERTISSEMENT Exigences électriques Pour prévenir d’éventuelles BLESSURES GRAVES ou LA MORT par suite d’électrocution ou d’un incendie : • S’assurer que l’ouvre-porte est hors tension et couper le courant au circuit AVANT de retirer le couvercle pour procéder à un branchement permanent. • La pose et le câblage de la porte de garage DOIVENT être conformes à tous les codes électriques et de construction locaux.
AVERTISSEMENT AVERTISSEMENT POSE - 10e OPÉRATION Pose du Système Protector ® S’assurer que l’ouvre-porte de garage est hors tension AVANT de poser le détecteur inverseur de sécurité. Pour prévenir des BLESSURES GRAVES ou LA MORT par suite d’une porte de garage qui se ferme : • Raccorder et aligner correctement le détecteur inverseur de sécurité. Ce dispositif de sécurité requis NE DOIT PAS être désactivé.
POSE DES SUPPORTS S’assurer que l’ouvre-porte est hors tension. Poser et aligner les supports de manière à ce que les détecteurs se fassent face l’un l’autre de part et d’autre de la porte du garage, le faisceau n’étant pas à une hauteur de plus de 6 po (15 cm) au-dessus du sol.
MONTAGE ET CÂBLAGE DES DÉTECTEURS INVERSEURS • Faire glisser un boulon à tête bombée et collet carré de 1/4 po-20 x 1/2 po dans la fente de chaque détecteur. Utiliser des écrous à oreilles pour fixer les détecteurs aux supports, avec les diffuseurs dirigés l’un vers l’autre de part et d’autre de la porte. S’assurer que le diffuseur n’est pas obstrué par une rallonge de support (Figure 5). • Serrer les écrous à oreilles à la main. • Acheminer les fils des deux détecteurs à l’ouvre-porte.
AVERTISSEMENT ATTENTION POSE - 11e OPÉRATION Fixation du Support de Porte Les portes de garage en fibre de verre, en aluminium ou en acier léger ont BESOIN d’être renforcées AVANT la fixation du support de porte. Il est conseillé de s’adresser au fabricant de la porte pour obtenir un nécessaire de renforts. Suivre les instructions qui correspondent au type de porte, comme il est illustré ci-dessous ou à la page suivante.
PORTES RIGIDES Prière de lire et de suivre les avertissements et les instructions de renforcements à la page précédente. Ils s’appliquent également aux portes rigides. • Centrer le support de porte sur le dessus de la porte, en l'alignant avec le support de linteau, comme il est illustré. Repérer soit les trous de gauche et de droite, soit les trous du haut et du bas.
POSE - 12e OPÉRATION Fixation de la biellette au chariot Poulie Min. de 8 po (20 cm) Suivre uniquement les instructions se rapportant au type de porte, comme illustré ci-dessous et à la page suivante. PORTE ARTICULÉE SEULEMENT • S'assurer que la porte du garage est complètement fermée. Tirer la poignée de déclenchement d’urgence pour détacher le chariot extérieur du chariot intérieur. Reculer le chariot extérieur (en l'éloignant de la poulie) d’au moins 8 po (20 cm), comme illustré aux Figures 1, 2 et 3.
POUR TOUTES LES PORTES RIGIDES 1. Assemblage des biellettes, Figure 4 : • Assembler les biellettes droite et courbée à leur plus grande longueur (2 ou 3 trous se chevauchant). • La porte étant fermée, raccorder la biellette droite au support de la porte à l'aide d'un axe de chape de 5/16 po x 1-1/4 po. • Faire tenir l'axe de chape avec un anneau d'arrêt. 2. Méthodes de réglage, Figure 5 : • Dans le cas d'une porte rigide, la course doit être réglée avant de raccorder la biellette au chariot.
AVERTISSEMENT AVERTISSEMENT RÉGLAGES - 1re OPÉRATION Réglage des courses d’ouverture et de fermeture Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • Un réglage erroné des courses de la porte de garage gênera un fonctionnement approprié du système d’inversion de sécurité.
AVERTISSEMENT AVERTISSEMENT RÉGLAGES - 2e OPÉRATION Réglage de la force Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • Une trop grande force sur la porte de garage gênera un fonctionnement approprié du système d’inversion de sécurité. • Ne JAMAIS augmenter la force au-delà du niveau nécessaire à la fermeture de la porte.
AVERTISSEMENT AVERTISSEMENT RÉGLAGES - 3e OPÉRATION Essai du système d’inversion de sécurité Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • On DOIT procéder à une vérification mensuelle du système d’inversion de sécurité. • Après avoir réglé une commande (force ou course), il peut être nécessaire de régler l’autre commande.
FONCTIONNEMENT AVERTISSEMENT IMPORTANTES CONSIGNES DE SÉCURITÉ AVERTISSEMENT Pour réduire le risque de BLESSURES GRAVES ou DE MORT : 1. LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS. 2. TOUJOURS garder les télécommandes hors de la portée des enfants. Ne JAMAIS laisser les enfants faire fonctionner les télécommandes ou les boutons-poussoirs de la commande de porte ou jouer avec ceux-ci. 3.
AVERTISSEMENT Utilisation de la commande de porte mural Ouverture manuelle de la porte AVERTISSEMENT Appuyer sur le bouton-poussoir éclairé pour ouvrir ou fermer la porte. Appuyer à nouveau pour inverser la porte durant le cycle de fermeture ou pour arrêter la porte pendant son ouverture.
AVERTISSEMENT LA PILE DE LA TÉLÉCOMMANDE ENTRETIEN DE L’OUVRE-PORTE DE GARAGE AVERTISSEMENT RÉGLAGES DE COURSE ET DE FORCE: Les conditions climatiques risquent de causer de petites modifications dans le AUGMENTER LA COURSE fonctionnement de la porte « DOWN » « UP » qui devra alors être réglée, en Commandes de course particulier pendant la (Panneau gauche) première année d’utilisation.
DÉFAUTS DE FONCTIONNEMENT 1. Ma porte ne se ferme pas et les ampoules de l’éclairage du moteur clignotent : Le détecteur inverseur de sécurité doit être raccordé et aligné correctement avant que l’ouvre-porte de garage n’entame la procédure de fermeture. • Vérifier que les détecteurs inverseurs de sécurité sont bien installés et dépourvus d’obstruction. Se reporter à la 10e étape de pose : Pose du Système Protector®.
Fil de sonnerie 1 2 Diagnostic situé sur le moteur Montage du détecteur inverseur 3 9 1 7 3 9 1 7 3 5 5 KG KG 1 Bouton « Learn » Détecteur inverseur Fiche Diagnostique 1 ÉCLAIR Cassure du fil des détecteurs de sécurité (coupé ou déconnecté). OU 2 ÉCLAIRS Court-circuit du fil des détecteurs de sécurité ou inversion des fils noir/blanc. 3 ÉCLAIRS Court-circuit de la commande de porte ou du fil. 4 ÉCLAIRS Léger mésalignement des détecteurs de sécurité (témoin LED faible ou clignotant).
PROGRAMMATION REMARQUE : Si cet ouvre-porte de garage Security✚® est utilisé avec une télécommande émettrice à code fixe, le dispositif technique que contient le récepteur de l’ouvre-porte et qui procure une protection contre les vols de code, se trouvera contourné. Le détenteur des droits d’auteur de cet ouvre-porte de garage n’autorise pas l’acheteur ni le fournisseur de la télécommande émettrice à code fixe à contourner ce dispositif technique.
Pour ajouter, reprogrammer ou modifier un NIP d’entrée sans clé REMARQUE : Votre nouvelle entrée sans clé doit être programmée de manière à faire fonctionner votre ouvre-porte de garage. UTILISATION DU BOUTON « LEARN » 1 9 1 7 1 1. Enfoncer et tenir le bouton « learn » sur le moteur. Le témoin lumineux learn s’allumera en continu pendant 30 secondes. 1 Pour modifier un NIP connu, existant Si le NIP existant est connu, il peut être modifié par une seule personne sans devoir utiliser d’échelle. 1.
PIÈCES DE RÉPARATION Pièces d’assemblage du rail 2 1 3 4 5 RÉF N° DE PIÈCE 1 2 3 4 5 6 4A1008 41C5141-1 41A5665-2 144C56 41A5807 12D598-1 6 183A163 DÉSIGNATION Maillon de raccord Chariot complet Rail complet Poulie de la chaîne Chaîne et câble Support en U NON ILLUSTRÉS Coussinets d’usure Pièces pour la pose 4 1 2 RÉF 3 6 5 NOT 7 ICE 10 9 8 13 12 11 N° DE PIÈCE 1 41A4166 2 950CD 3 4 5 10A20 29B137 41A2828 6 41B4494-1 7 41A5047 8 41A5047-2 9 41A5034 10 11 12 13 178B34 12B
Pièces d’assemblage du moteur 1 2 20 4 3 8 16 19 17 18 16 6 5 7 11 13 15 9 10 3 Contact (fermeture) 14 INTERRUPTEUR DE FIN DE COURSE Fil brun Fil gris DN UP Pignon menant Contact de fin de course central 12 RÉF.
ACCESSOIRES 7702C Télécommande à 3 - Bouton SECURITY✚® : 953CD Nécessaire pour un garage SANS porte d’accès. Comprend agrafe de pare-soleil. Mini-télécommande à 3 - Bouton SECURITY✚® : 956CD 760C Interrupteur à clé extérieur : Pour ouvrir automatiquement la porte du garage de l’extérieur sans la télécommande. 7708C Rallonge de rail de 8 pieds : Pour permettre à une porte de 8 pieds (2,44 m) de s'ouvrir complètement.
SERVICE CHAMBERLAIN À VOTRE DISPOSITION COMMENT COMMANDER DES PIÈCES DE RECHANGE NOTRE IMPORTANTE ORGANISATION DE SERVICE APRÈS-VENTE COUVRE LES ÉTATS-UNIS ET LE CANADA Les prix de vente seront fournis sur demande, ou bien les pièces seront expédiées au prix en vigueur et vous seront facturées en conséquence.