User's Manual
23
Installation
STEP 13 Install the Protector System
®
(continued)
OPTION B WALL INSTALLATION
If additional clearance isneeded an extension bracket (notprovided) or wood blockscan be used. Make
sure each brackethas the same amount of clearance so theywill align correctly.
1. Position the sensor bracketagainst the wall with the curved arms facing the door. Make sure
there is enough clearance for the beam to be unobstructed. Mark holes.
2. Drill 3/16 inch pilot holes for each sensor bracketand attach the sensor brackets to the wall using
lag screws(not provided).
3. Slide the carriage boltinto the sloton each sensor.
4. Insert the boltthrough the hole in the sensor bracketand attach with the wing nut. The lenseson
both sensors should pointtoward each other.Make sure the lensis not obstructed by the sensor
bracket.
(Not provided)
No more than
6 inches (15 cm)
1
2
Inside
G
arage
Wall
(Not provided)
Lens
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
3
4
OPTION C FLOOR INSTALLATION
Use an extension bracket(notprovided) or wood block to raise the sensor bracketifneeded.
1. Carefully measure the position of both sensor brackets so they will be the same distance from the
wall and unobstructed.
2. Attach the sensor brackets to the floor using concrete anchors (not provided).
3. Slide the carriage boltinto the sloton each sensor.
4. Insert the boltthrough the hole in the sensor bracketand attach with the wing nut. The lenseson
both sensors should pointtoward each other.Make sure the lensis not obstructed by the sensor
bracket.
I
nsid
e
G
arage
Wa
l
l
(Not provided)
1 2
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
3
4