Operation Manual
Table Of Contents
- Owner's Manual
- CONTENTS
- Preparation
- Assembly
- Installation
- STEP 1 Determine the header bracket location
- STEP 2 Install the header bracket
- STEP 3 Attach the rail to the header bracket
- STEP 4 Position the garage door opener
- STEP 5 Hang the garage door opener
- STEP 6 Install the light bulbs
- STEP 7 Attach the emergency release rope and handle
- STEP 8 Install the door bracket
- STEP 9 Connect the door arm to the trolley
- STEP 10 Install the door control
- STEP 11 Wire the door control to the garage door opener
- STEP 12 Attach the warning labels
- STEP 13 Install the Protector System®
- STEP 14 Wire the Safety Reversing Sensors
- STEP 15 Connect power
- STEP 16 Ensure the safety reversing sensors are aligned
- STEP 17 Ensure the door control is wired correctly
- Adjustments
- Operation
- Maintenance
- Troubleshooting
- Accessories
- Warranty
- Contact Information
- Repair Parts
- Spanish

10
Installation
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properlybalanced and lubricated garage door. An
improperly balanced door may NOT reverse when required and could result in SEVERE
INJURY or DEATH.
3. ALL repairs to cables,spring assembliesand other hardware MUST be made bya trained
door systemstechnician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing
opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above floor.
6. Mount the emergency release within reach,but at least6 feet (1.83 m) above the floor and
avoiding contact with vehiclesto avoid accidental release.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVERwear watches,rings or loose clothing while installing or servicing opener.They could
be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out ofreach of children at minimum height of5 feet (1.5 m).
• away from ALL moving parts ofthe door.
10. Place entrapment warning label on wall next to garage door control.
11. Place manual release/safetyreverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact
with a 1-1/2" (3.8 cm) high object(or a 2x4 laid flat) on the floor.
13. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnectALL
electricpower BEFORE performing any service or maintenance.
14. DO NOT enable the Timer-to-Close functionality if operating either one-piece or swinging
garage doors.To be enabled ONLY when operating a sectional door.