® S P E C I F I C A T I O N S DESCRIPTION ALKALINE PRIMARY BATTERY - LR03 SPECIFICATION AAA SIZE /1.5V MAKERS SPECIFICATION LR03 PART NO. C/0 MODEL NO. ALLKEY-LR03-2017 SPECIAL ARTICLES MANAGER CHECK APPROVAL JunPing Liu Lihui Chen HangJun Wu 2017/1/3 2017/1/3 2017/1/3 TERM OF VALIDITY MAKER ADDRESS Shenzhen ALLKEY Battery Co.
RECODRD OF REVISION Part Name Part No. Alkaline Primary battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page Manager Check Approval Version JunPing Liu Lihui Chen HangJun Wu C/0 Version Reason to modify 4/F, Hongwan Commercial Building, 4235# Bao'an District,518126, Shenzhen Tel:086-0755-29957377 http://www.allkeybattery.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 2/9 1. Application This specification is applied to inspection and approval of the alkaline primary batteries LR03 which is manufactured by Shenzhen ALLKEY Battery Co., Ltd Alkaline Batteries Branch. 2.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 3/9 5. Mechanical Characteristics and standard 5.1) Appearance & Dimensions (Unit:mm) 1) Appearance The battery visually inspected by unaided eye 30cm away from battery. The battery shall be free from dents, scratch, rust and extruded internal compounds, such as sealing compounds and etc,and serious displacement of artwork.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 4/9 5.2) Schematic Diagram (Internal structure Figure) No Part Name Materials 1 Steel Can Ni-plated Steel 2 Cathode Pelet MnO2 3 separator textile 4 Anode Gel Zn+KOH 5 Current collector Brass+In 6 Label PVC 7 Seal nylon 8 Negative cap Ni-plated Steel 5.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 5/9 5.4) User Drop Test This test simulates the situation when a battery is accidentally dropped. The batteries shall be no explosion and leakage after hour. Method) Undischarged test batteries shall be drop a height of 1M onto a concrete surface. Each test battery shall be dropped two times at X, Y, Z axes. 6. Electrical characteristics and standard.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 6/9 6.3) Graph of Service Output characteristics(Discharge Curve) Voltage Voltage 3.9 Ohms 24h/d Voltage 5.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 7/9 7. Environmental Characteristics and standard 7.1) Leakage 1) High temperature The batteries shall be stored in the unpacked condition under the 60±2℃,related humidity 90% for 30 days. After storage visually inspecting shall be no deformation, electrolyte leakage findable. - Sample size N=10, Ac=0, Re=1.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY-LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 8/9 9. Safety test for intended or reasonably foreseeable misuse 9.1) Storage After Partial Use This test simulates the situation when an appliance is switched off and the installed batteries are partly discharged. These batteries may be left in the appliance for a long time. Method) Undischarged battery is discharged during 2hours by 5.
SPECIFICATIONS Part Name Part No. Alkaline Primary Battery - LR03 ALLKEY--LR03-2017 Prepared Date Approved Date Version Page 2017/1/3 2017/1/3 C/0 9/9 9.4) Over discharge ( Battery mix-up fresh & used or other type battery) This test simulates the condition when one discharged battery is series-connected with three other undischarged batteries.