User's Manual

18
Troubleshooting
Troubleshooting
Onoccasionyourmachinemaynotoperateasexpected.
Usethechecklistbelowbeforeyoudecidethatamechanicalorelectricalfailurehasoccurred.
Checklist
1. Arethemaindisconnectswitches,breakers,ormotoroverloadsturnedON?
2. ArethemainwaterandsteamsuppliesturnedON?
3. Arethedrainvalvesclosed?
4. Arethespraypipesandrinsenozzlesclean?
5. Arethespraypipesintheproperlocations?
6. Arethepumpintakesclean?
7. Arethescrapscreenscleanandinplace?
8. Arethethermostatscorrectlyadjusted?
9. Arethehighlimittemperaturethermostatsreset?
10. Arethedoorsfullyclosed?
11. Aretheconveyorshut-offanddriveassembliesinoperatingcondition?
12. Arethechemicalsuppliesadequatelylled?
Ifaproblemstillexistsafterverifyingthechecklist,refertothefollowing
CONDITION CAUSE SOLUTION
Conveyorwillnotrun Doornotclosed................................... Makesuredoorsarefullyclosed
Doorsafetyswitchfaulty.................... Contactyourserviceagency
Startswitchfaulty............................... Contactyourserviceagency
MainswitchOFF................................ Checkdisconnect
ControlpanelpowerswitchOFF........ FlipswitchON
Conveyorshut-offshelfoperated........ Moveshelftowardtunnelofmachine
Motoroverloadprotectortripped........ Resetoverloadincontrolcabinet
Greenstartbuttonnotpressed............ Pressgreenstartbutton