OWNER’S MANUAL 6900 Starting Watts/5500 Running Watts (Gasoline) 6250 Starting Watts/5000 Running Watts (LPG) Manual Start Limited Wa rra Year n ree ty Th DUAL FUEL GENERATOR Ga ra SAVE THESE INSTRUCTIONS Important safety instructions are included in this manual. n tí a li m os U.S. Patent No. D710,802 es it a d a d e tr añ MODEL NUMBER 100231 MADE IN CHINA REV 100231-20171114 12039 Smith Ave. Santa Fe Springs CA 90670 USA / 1-877-338-0999 www.championpowerequipment.
AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation.
100231 6900 Starting Watts/5500 Running Watts (Gasoline) 6250 Starting Watts/5000 Running Watts (LPG) Manual Start DUAL FUEL GENERATOR TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Manual Conventions. . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Fuel Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Safety Label Locations . . . . . . . . . . . . . . . . . . .
ENGLISH 100231 INTRODUCTION Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
100231 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death. DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
ENGLISH 100231 SAFETY RULES WARNING Read this manual thoroughly before operating your generator. Failure to follow instructions could result in serious injury or death. WARNING The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm. DANGER Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death.
100231 ENGLISH WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go. Unintentional startup can result in entanglement, traumatic amputation or laceration. Broken bones, fractures, bruises or sprains could result. When starting engine, pull the starter cord slowly until resistance is felt and then pull rapidly to avoid kickback. DO NOT start or stop the engine with electrical devices plugged in.
ENGLISH 100231 SAFETY RULES Fuel Safety DANGER GASOLINE, GASOLINE VAPORS AND LIQUID PETROLEUM GAS (LPG) ARE HIGHLY FLAMMABLE AND EXPLOSIVE. Fire or explosion can cause severe burns or death. Unintentional startup can result in entanglement, traumatic amputation or laceration. Gasoline and Gasoline Vapors (Gas): – – – – GAS IS HIGHLY FLAMMABLE AND EXPLOSIVE. Gas can cause a fire or explosion if ignited. Gas is a liquid fuel but it’s vapors can ignite.
100231 ENGLISH SAFETY RULES Safety Label Locations These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Champion Power Equipment’s customer service department for possible replacement. A C B E E D F G GN-SF-T-002.
ENGLISH 100231 CONTROLS AND FEATURES Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1 8 9 2 7 3 6 4 5 7 (1) Gas fuel tank – 6.1 gal. (23 L) capacity fuel tank. (6) Oil filler cap – Check and fill engine oil level. (2) Choke – Used to start the engine. (7) Power panel – See “Power Panel” section.
100231 ENGLISH CONTROLS AND FEATURES Power Panel 1 2 3 A 4 5 (1) Fuel selector switch – Used to select and turn on gas or LPG fuel source. (2) Engine switch – Used to start or stop the generator. (3) Intelligauge – Three mode digital meter for displaying running hours, voltage and hertz. (4) LPG hose connector – Used to connect LPG hose to generator.
ENGLISH 100231 CONTROLS AND FEATURES Parts included Your 100231 dual fuel generator ships with the following parts: Wheel kit – – – – – – 8 in. wheel . . . . . . . . . . . . . . . . . . Pin roll Ø16 x Ø10 x 97 (for wheels) “R” shape pin Ø2 x 33 . . . . . . . . . Support leg w/vibration mounts . . . . Flange bolt (M8x16 for support leg) . Flange lock nut (M8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100231 ENGLISH Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please have your serial number and model number available. ASSEMBLY Install the Support Leg 1. Attach the support leg to the generator frame with flange bolts (M8x16) and flange lock nuts (M8). 2.
ENGLISH 100231 ASSEMBLY Add Engine Oil CAUTION DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty. NOTE The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing. NOTE The recommended oil type is 10W-30 automotive oil. 1.
100231 ENGLISH Add Fuel (Gas) 1. Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. 2. DO NOT mix oil with fuel. 3. Clean the area around the fuel cap. 4. Remove the fuel cap. 5. Slowly add fuel to the tank. DO NOT OVERFILL. Fuel can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for fuel expansion, more than ¼ in. (6.4 mm) is recommended.
ENGLISH 100231 ASSEMBLY Connecting a LPG Cylinder 1. Make sure the fuel valve on the generator is in the off position. 2. Attach the LPG hose (included) to the LPG hose connector on the side of the generator and tighten with a 19 mm or adjustable wrench. Important: DO NOT use tape or any other type of sealant to seal LPG hose connection. 3. Remove the safety plug or cap from the cylinder valve. 4. Attach the other end of the hose to the LPG connector on the cylinder and hand tighten. 5.
100231 ENGLISH OPERATION Generator Location Grounding NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, generators must be registered with the local utility. Generators used at construction sites may be subject to additional rules and regulations. Generators should be on a flat, level surface at all times.
ENGLISH 100231 OPERATION Fuel Selector Switch Starting the Engine in ambient > 15°C (59°F) The fuel selector switch on the front panel of the generator is designed specifically to choose between the fuel source desired, Gas or Propane (LPG). To select a fuel source simply slide the switch cover to either the right or left, and this will uncover the fuel valve of the fuel selected. The propane fuel valve (A) is to the left of the switch cover.
100231 ENGLISH OPERATION LPG Connecting Electrical Loads 1. Make certain the generator is on a flat, level surface. 2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on. 3. Fully open the LPG cylinder fuel knob. 4. Turn the LPG fuel valve to the “ON” position. 5. Press the engine switch to the “ON” position. 6. RECOIL START: Move the choke lever to the “100% Choke” detent position. a.
ENGLISH 100231 OPERATION Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the amount of power you need to keep your items running. 3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2.
100231 ENGLISH OPERATION Stopping the Engine Operation at High Altitude 1. Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on. 2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator. 3. Turn the fuel valve to the “OFF” position if operating by gas. 4. Turn the LPG cylinder knob to the “CLOSE” or off position if operating by LPG. 5.
ENGLISH 100231 MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic maintenance. WARNING Never operate a damaged or defective generator. WARNING Oil Cont’d. NOTE Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking. Tampering with the factory set governor will void your warranty. WARNING Improper maintenance will void your warranty.
100231 ENGLISH MAINTENANCE AND STORAGE Spark Arrester Maintenance Schedule 1. Allow the engine to cool completely before servicing the spark arrester. 2. Remove the three screws holding the cover plate which retains the end of the spark arrester to the muffler. 3. Remove the spark arrester screen. 4. Carefully remove the carbon deposits from the spark arrester screen with a wire brush. 5. Replace the spark arrester if it is damaged. 6.
ENGLISH 100231 MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the gas tank. 2. Be sure all appliances are disconnected from the generator. 3. Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor. 4. Turn the gas fuel valve to the “Off” position. 5.
100231 ENGLISH SPECIFICATIONS Engine Specifications – – – – Model . . . . . . Displacement . Type . . . . . . . Start Type . . . . . . . . . . . . . . . . . . . . . . . Maintenance Valve Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YF188FD-L_G . . . . . .389cc .4-Stroke OHV . Manual Start Generator Specifications An Important Message About Temperature – – – – – – – – Model . . . . . . . . . . . .
23 75 76 78 79 80 81 69 70 71 72 68 74 67 73 95 76 89 90 91 92 93 94 96 82 83 87 88 77 97 84 85 86 3 111 110 107 108 109 105 21 106 98 99 69 100 2 1 61 5 112 76 101 102 103 104 60 59 58 24 57 56 4 54 63 113 114 111 120 119 55 62 64 52 118 117 116 115 53 65 8 9 10 11 7 6 6 66 51 23 25 26 48 126 27 125 49 124 121 122 123 50 24 20 21 22 12 13 127 47 14 46 33 29 45 32 44 43 34 35 36 44 28 15 16 17 18 19 42 37 38 31 30 41 40 35 39 SPECI
100231 ENGLISH Parts List # Part Number Description Qty # Part Number Description 1 2.06.006 Clamp, Ø7 x Ø1 2 67 1.5789.0612.1 Flange Bolt M6 x 12, Black Qty 3 2 152.070014.05 Pipe, Reversal Valve, 810 mm 1 68 152.200800.09.2 Decorative Plate 1 3 2.05.001 Clamp, Ø8 x 6.5 2 69 152.070031.00 Jacket, LPG Hose 3 4 152.070013.03 Pipe, Air Cleaner, 135 mm 1 70 65271.0.8.2 Frame 1 5 2.06.004 Clamp, Ø8 x Ø1 1 71 1.6177.1.10 Lock Nut M10, Flange 4 6 1.5789.
25 99 89 2 1 3 102 103 104 105 91 106 107 98 12 4 24 5 25 6 7 26 108 109 100 8 27 9 28 91 10 11 29 90 30 101 12 31 89 12 88 13 87 14 32 86 96 63 85 15 64 95 16 17 33 65 66 94 67 18 34 68 69 93 70 19 35 71 72 92 97 74 20 12 73 36 75 16 30 76 2 37 77 78 21 79 81 45 22 38 80 46 82 47 49 23 84 48 23 83 39 50 51 52 12 44 53 43 54 42 55 56 41 57 40 58 59 60 61 62 SPECIFICATIONS ENGLISH 100231 Engi
100231 ENGLISH # Part Number Description Qty # Part Number Description 1 21.061300.00 Handle, Recoil, Soft 1 61 45.020001.02 Breather Tube 2 1.5789.0608 Flange Bolt M6 x 8 62 45.020100.00 Bolt, Cylinder Head Cover 3 46.061100.00.2 Cover, Recoil Starter, Black 4 45.060005.00 Spring, Recoil Starter 5 45.061102.00 Reel, Recoil Starter 6 2.10.003 Rope Ø5 x 1550 7 45.060003.00 Spring, Ratchet 8 45.060002.00 Starter Ratchet, Steel 9 45.060009.
27 a c e SWITCH d 1 2 3 4 f BLACK Br BROWN B Y YELLOW B/W BLACK WHITE BLUE W/G WHITE GREEN L GREEN G/Y GREEN YELLOW G W/L WHITE BLUE R RED W WHITE B/G BLACK GREEN ON OFF COMBINATION SWITCH LPG GAS b GENERATOR BLOCK FW MW2 EXW + ENGINE BLOCK W R Y W L L R MW1 L Y Y L L W R IGNITION COIL B R multi-purpose meter B B AVR W SPARKING PLUG L B 3 1 Br Br R G/Y G/Y W CHARGE COIL 4 2 23A Charger 250V 23A DOUBLE POLE W B L B B B W W d a W b W/G f
100231 ENGLISH TROUBLESHOOTING Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Low oil level Fill crankcase to the proper level Generator will not start; Generator starts but runs roughly Generator shuts down during operation Generator cannot supply enough power or overheating No AC output Repeated circuit breaker tripping Place generator on a flat, level surface Choke in the wrong posi
WARRANTY WARRANTY* CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as proof of purchase. Please submit your warranty registration and your proof of purchase within ten (10) days of the date of purchase.
Champion Power Equipment, Inc. (CPE), The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emission regulations.
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter. 2.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this warranty Fuel Metering System Fuel regulator, Carburetor and internal parts Air Induction System Air cleaner, Intake manifold Ignition System Spark plug and parts, Magneto ignition system Exhaust System Exhaust manifold, catalytic converter Miscellaneous Parts Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed systems.