Use and Care Manual

100519 - 6250W PORTABLE INVERTER GENERATOR
CONTROLS AND FEATURES
12
Control Panel
1. Engine Switch – Used to put in START mode or STOP the
generator.
2. Economy Mode Switch – Enables/disables automatic idle
control.
3. Choke – Used to start a cold engine.
4. Intelligauge – Four mode digital meter for displaying
voltage, frequency (hertz), run time, and total run time.
5. AC Overload Reset Button – Used to re-energize
receptacles after overload fault.
6. Output Indicator Light – Remains ON during normal
operating conditions. Turns OFF when generator is
overloaded.
7. Overload Indicator Light – When ON generator is
overloaded and power to receptacles is cut.
8. Oil Warning Indicator Light – When ON engine will shut
down and not run. Check oil level.
9. Circuit Breakers (Push Reset) – Protects the generator
against electrical overloads.
RECEPTACLES
A
z
12V DC, 8 Amp (Automotive)
May be used to supply electrical power for
operation of 12 Volt DC, 8 Amp electrical
loads.
B
C
(4×) 120V AC, 20A GFCI (NEMA 5-20R)
May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single
phase, 60 Hz electrical loads.
C
Y
120/240V AC, 30A Locking (NEMA L14-30R)
May be used to supply electrical power for
operation of 120/240 Volt AC, 30 Amp, single
phase, 60 Hz electrical loads.
! WARNING
Do not operate a device while it is plugged into the 12V DC
outlet. Prolonged exposure to engine exhaust can cause
serious injury or death. While charging a device do no place
on the exhaust side of the generator. Extreme heat caused
by exhaust can damage the device, and cause a potential
fire hazard.