100558 - 3500W WIRELESS START GENERATOR
OPERATION
19
! CAUTION
Use unleaded gasoline with a minimum octane rating of 85
and an ethanol content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and gasoline.
DO NOT overfill the tank. Fill tank to approximately ¼ in.
(6.4 mm) below the top of the tank to allow for gasoline
expansion.
DO NOT pump gasoline directly into the generator at the
pump. Use an approved container to transfer the gasoline to
the generator.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
! WARNING
Pouring gasoline too fast through the fuel screen may result
in gasoline splashing over the generator and operator while
filling.
"
NOTICE
The generator engine works well with 10% or less ethanol
blend gasoline. When using ethanol-gasoline blends there
are some issues worth noting:
Ethanol-gasoline blends can absorb more water than
gasoline alone.
These blends can eventually separate, leaving water or
a watery goo in the tank, fuel valve and carburetor. The
compromised gasoline can be drawn into the carburetor
and cause damage to the engine and/or potential
hazards.
If a fuel stabilizer is used, confirm that it is formulated to
work with ethanol-gasoline blends.
Any damages or hazards caused by using improper
gasoline, improperly stored gasoline, and/or
improperly formulated stabilizers, are not covered by
manufacturer’s warranty.
It is advisable to always shut off the gasoline supply and
run the engine to starvation after each use. See Storage
instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate
ground to help prevent electric shock.
! WARNING
Failure to properly ground the generator can result in
electric shock.
A ground terminal connected to the frame of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to
ensure compliance with local electrical codes.
Neutral Floating*
Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
The generator (stator winding) is isolated from the frame
and from the AC receptacle ground pin.
Electrical devices that require a grounded receptacle pin
connection will not function if the receptacle ground pin is
not functional.
Neutral Bonded to Frame*
Neutral circuit IS electrically connected to the frame/ground
of the generator.
The generator system ground connects lower frame
cross-member below the alternator. The system ground is
connected to the AC neutral wire.
* See your model’s control panel for specified type of grounding.
OPERATION
Generator Location
NEVER operate the generator inside any building, including
garages, basements, crawlspaces and sheds, enclosure or
compartment, including the generator compartment of a
recreational vehicle. Please consult your local authority. In
some areas, generators must be registered with the local
utility. Generators used at construction sites may be subject
to additional rules and regulations. Generators should be on
a flat, level surface at all times. (Even while not in operation)
Generators must have at least 5 ft. (1.5 m) of clearance from
all combustible material. In addition to clearance from all
combustible material, generators must also have at least 3 ft.
(91.4 cm) of clearance on all sides to allow for adequate cooling,
maintenance and servicing. Generators should never be started
or operated in the back of a SUV, camper, trailer, in the bed of
a truck (regular, flat or otherwise), under staircases/stairwells,