Full Product Manual

100558 - 3500W WIRELESS START GENERATOR
MAINTENANCE
26
! CAUTION
Failure to clean the spark arrestor will result in degraded
engine performance.
"
NOTICE
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required.
When ordered, spark arrestors are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest-covered
land, brush-covered land, or grass-covered land unless the
engine is equipped with a spark arrestor.
Adjusting the Governor
! WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. Contact our
Technical Support Team at 1-877-338-0999 for all other
service and/or adjustment needs.
Generator Battery
Your generator is equipped with an automatic battery charging
circuit that charges the battery while the engine is running.
The battery will maintain a proper charge if the unit is used on
a regular basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle charger
or battery maintainer (not included) to keep the battery properly
charged.
Maximum charging rate should not exceed 1.5 amps. Follow
the instructions included with the battery charger. The battery
should be fully charged at least once per month. If the battery
is not able to start the engine, it can be started by manually
pulling the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a
standard automotive style battery charger for re-charging
before it can be used.
Disconnect the Battery
1. Remove the protective cover from the black (–) battery
lead.
2. Disconnect the black (–) lead from the black (–) terminal on
the battery and store the cap screw and nut.
3. Repeat steps 1-2 for the red (+) battery lead.
4. Store the battery in a cool, dry place.
DELETE "NATIONAL FOREST" NOTICE IF CANADA ONLY ITEM
Charge the Battery
For a generator equipped with batteries for electric starting,
proper battery maintenance and storage should be followed.
A trickle charger or battery maintainer should be used to charge
the battery while the generator is in storage. Maximum charging
rate should not exceed 1.5 amps. Follow the instructions
included with the trickle charger or battery maintainer.
The battery should be fully charged at least once per month.
Remote Control Battery
"
NOTICE
Always purchase the correct size and grade of battery
most suitable for the intended use.
Clean the battery contacts and also those of the device
prior to battery installation.
Remove batteries from equipment which is not to be
used for an extended period of time.
Remove batteries if consumed or if product is to be left
unused for a long time.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating in
adverse conditions.
Contact our Technical Support Team at 1-877-338-0999
to locate the nearest CPE certified service dealer for your
generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
# Check oil level
# Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
# Change oil
EVERY 50 HOURS OR ANNUALLY
# Clean air filter
# Change oil if operating under heavy load or in hot
environments