Product Manual A

200962 - 2500W DUAL FUEL INVERTER GENERATOR
OPERATION
24
Stopping the Engine
Gasoline
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the fuel vent lever to the “OFF” position.
4. Turn the dial counterclockwise to the “STOP” position.
Important: Always ensure that the dial and fuel vent on the fuel
cap are in the “OFF” position when the generator is not in use.
Propane
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Close the fuel valve on the propane cylinder.
4. Turn the dial counterclockwise to the “STOP” position.
NOTICE
If the generator will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine and
fuel storage.
Moving the Generator
ALWAYS turn the generator off and ensure the fuel valve is
closed.
ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 15-30
minutes).
Lift unit up by the carrying handle and move to the desired
location.
Do not drop or strike unit or place under heavy objects.
Failure to follow these instructions could result in personal
injury or damage to the generator.