200991 - 4500W DUAL FUEL INVERTER GENERATOR
OPERATION
24
Electric Start
Cold Engine Start
3. Move the EZ Start dial to the “CHOKE” position.
4. Press and hold the yellow ignition switch on the EZ Start Dial
toward the center of the dial. Release as the engine begins to
start. If the engine fails to start within five seconds, release
the switch and wait at least ten seconds before attempting to
start the engine again.
5. Do not over-choke. As soon as engine starts, turn the EZ
Start dial to the “RUN” position.
Warm Engine Start
3. Turn the EZ Start dial to the “RUN” position.
4. Press and hold the yellow ignition switch on the EZ Start Dial
toward the center of the dial. Release as the engine begins to
start. If the engine fails to start within five seconds, release
the switch and wait at least ten seconds before attempting to
start the engine again.
NOTICE
Keep EZ Start dial in “CHOKE” position for only 1 pull of the
recoil cord. If generator does not start after first pull, rotate the
EZ Start dial to the “RUN” position for the next three pulls. Too
much choke leads do spark plug fouling and engine flooding.
This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient >
86°F (30°C): Rotate the EZ Start dial to 75% of the full choke
position for only one pull of the recoil cord. If generator does
not start after first pull, rotate the dial to the RUN position
for the next three pulls. Too much choke leads do spark plug
fouling and engine flooding. This will cause the engine not to
start.