Owners Manual

200991 - 4500W DUAL FUEL INVERTER GENERATOR
OPERATION
25
NOTICE
For gas starting in cold ambient < 59°F (1C): The choke
must be in 100% of the “CHOKE” position for manual start
procedures. Do not over-choke. As soon as the engine starts,
turn the EZ Start dial to the “RUN” position.
NOTICE
If the engine starts but does not continue to run, make certain
that the generator is on a flat, level surface. The engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
Starting the Engine: Propane (LPG)
NOTICE
Turn the generator off before attempting to switch from
gasoline to LPG operation.
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Open the fuel valve on the propane cylinder.
Manual Start
Cold Engine Start
4. Move the EZ Start dial to the “CHOKE” position.
5. Slowly pull the starter cord 3-5 times to prime the engine.
6. Turn the EZ Start Dial to the “RUN” position.
7. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
Warm Engine Start
4. Turn the EZ Start dial to the “RUN” position.