OPERATOR'S MANUAL MODEL #100593 3200 Portable Power Station REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com READ AND SAVE THIS MANUAL. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
Table of Contents 100593 - 3200 Portable Power Station TABLE OF CONTENTS Maintenance................................................. 25 Cleaning the Power Station............................. .......... 25 Introduction.................................................... 3 Storage.................................................. .......... 25 Safety Definitions........................................... 3 Specifications...................................... .........
Introduction 100593 - 3200 Portable Power Station INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service. The purpose of safety symbols is to attract your attention to possible dangers.
Important Safety Instructions 100593 - 3200 Portable Power Station IMPORTANT SAFETY INSTRUCTIONS WARNING Do not use Power Station for medical life support uses. WARNING In case of emergency, call 911 immediately. Cancer and Reproductive Harm – www.P65Warnings.ca.gov NEVER use this product to power life support devices or life support appliances. WARNING Inform your electricity provider immediately if you or anyone in your household depends on electrical medical equipment to live.
Important Safety Instructions 100593 - 3200 Portable Power Station Lithium-ion Battery Safety WARNING DANGER When using the Power Station: – Always use in a dry well ventilated area while in use and do not obstruct fan openings on unit. Inadequate ventilation may cause execessive heat and damage the unit. Electrolyte inside the battery is harmful to skin and eyes. Electrolyte may pose an increased risk of harm if not handled properly.
Important Safety Instructions 100593 - 3200 Portable Power Station – Never use Power Station or charger in the presence of explosive atmospheres (gaseous fumes, dust or flammable materials). WARNING – Do not use a Power Station or appliance that is damaged or modified. Damaged or modified internal batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury. – Never leave the Power Station unattended while charging.
Important Safety Instructions 100593 - 3200 Portable Power Station In case of battery damage: – If damaged, the internal battery may emit hazardous fumes. If fumes are present, move Power Station to a well-ventilated area. – Do not try to repair the Power Station or replace the battery. Safe disposal of Lithium-ion battery: – Lithium-ion batteries contain elements that pose health risks to individuals if they are allowed to leach into the ground water supply.
Important Safety Instructions 100593 - 3200 Portable Power Station Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement. F F A B D E C Top Back Inside LABEL DESCRIPTION A Safety Symbols WARNING APN Colors ADVERTISSEMENT 3458-L-SF Rev A Do not overcharge the internal battery. See Operator’s Manual.
Important Safety Instructions 100593 - 3200 Portable Power Station Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product. Eye protection.
Important Safety Instructions 100593 - 3200 Portable Power Station SYMBOL MEANING Wet Conditions Alert. Do not operate Power Station in wet conditions. This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws prohibit disposal of Li-ion batteries in ordinary trash. In the United States and Canada, a large network of over 30,000 battery drop-off locations may be found at www.call2recycle.
Important Safety Instructions 100593 - 3200 Portable Power Station Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING SYMBOL Hold for 3 seconds to power ON/ OFF. Press for 1 second to power AC outlets ON/OFF.
Important Safety Instructions 100593 - 3200 Portable Power Station Quick Start Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. 1 2 4 3 3s 1 1x Using the Power Station NOTICE 3 2 3s APN Turning 3607-L-PR Rev A Size 110 x 28 mm off the Power Station Colors 1. Turn off and unplug all connected electrical loads.
Controls and Features 100593 - 3200 Portable Power Station CONTROLS AND FEATURES Read this operator’s manual before operating your Power Station. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Power Station 1 4 6 1 2 7 8 5 9 3 10 1. Carrying Handle(s) – Used to lift or carry the unit. 7. DC Fast Charge - MPPT Solar - 10V-28V DC, 25A MAX (APP Anderson Power Pole DC) – Used to charge the Power Station from solar panel(s).
Controls and Features 100593 - 3200 Portable Power Station Control Panel 1 E A 6 1 H W 2 % C B D F F 12 1234 5 3 DC Output 4 2 AC Output 2 1. Intelligauge – See Intelligauge section. RECEPTACLES 2. Cover Lock – Push the the cover to unlock and lift to open or push to close. Will click upon close or open. 3. On/Off Button – Turns the Power Station ON/OFF when pressed for three seconds. Powers AC receptacles ON/OFF when pressed one time. DC receptacles are always live.
Controls and Features 100593 - 3200 Portable Power Station Intelligauge This meter displays a variety of info such as input/output power, charge/discharge times, as well as faults, errors, and protection codes to help diagnose malfunctions in the Power Station. The top displays input and output information. The bottom displays output percent (%), battery level, and icons related to which outlets are in use, specific warnings or other faults and functions.
Controls and Features 100593 - 3200 Portable Power Station Display Modes MODE DESCRIPTION 1 2 Charging (Hours) Example: 4.0 Hours to charge to full, 0 watts out, battery is at 10% % 1 2 Charging (Watts) Example: 384 Watts charging in, 0 watts out, battery is at 10% 2 Example: 2.
Controls and Features 100593 - 3200 Portable Power Station Indicators MODE DESCRIPTION 1 THD Shield Enabled (Default Mode), AC Output OFF Example: THD Shield enabled icon will always be steady blue. DC ports are always live. 2 % This is the default display upon startup. 1 THD Shield Enabled, THD Fault >5% W Example: THD Shield enabled icon will always be steady blue. “THD” steady red. AC output shut off due to THD above 5%.
Controls and Features 100593 - 3200 Portable Power Station MODE DESCRIPTION 1 W 2 Low Temperature Warning Example: Steady red when the Power Station has experienced a low temperature event. % 1 W 2 LED ON Example: The LED icon is showing the LED is on. % 1 12V DC and USB Fault Locators The numbers below the 12V DC and USB fault indicators specify which port is experiencing a fault. See figure to the right.
Controls and Features 100593 - 3200 Portable Power Station Industry Canada: ICES-003/NMB-003 This device complies with Industry Canada license - exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Parts Included Accessories AC Charge Cable....................................................
Initial Use 100593 - 3200 Portable Power Station INITIAL USE 1. Remove the rubber plug covering the AC input port on the AC Charging module. Your Power Station must be charged before first use. 2. Plug the AC Charging Cable into the AC input port on the back of the Power Station. If you have any questions regarding the use of your Power Station, call our Technical Support Team at 1-877-338-0999. Please have your serial number and model number available. Unpacking 1.
Initial Use 100593 - 3200 Portable Power Station Recommended Solar Panels 1. Remove the rubber plug covering the DC input port and connect the APP end of the Easy Connect DC Solar Charge Harness (included) to the APP input port on the back of the Power Station. NOTICE It will not damage, and often times is necessary, to use more than the 440W of solar panels to achieve actual 440W of charging. Always use panels with the same nominal voltage rating when using multiple solar panels. 2.
Initial Use 100593 - 3200 Portable Power Station OPERATION 4. To turn THD Shield off, press THD Shield button 5x within three seconds. Using the Power Station 1. Press and hold the power button for three seconds, until display illuminates. 5. Plug in desired devices. Standby Mode The Power Station will remain in standby mode for 4 hours, then shut off if it does not supply at least 5 watts to an external device or appliance. It will not shut off if it is plugged in and charging. 2.
Initial Use 100593 - 3200 Portable Power Station Connecting Electrical Loads 4. If overload is due to high THD, the AC outlet icon and “THD” will remain steady red. See THD Shield (Total Harmonic Distortion) section. WARNING Always remember to plug your appliances directly into the Power Station and do not connect any of the several Power Station “outputs” into any electrical outlet or connect to the circuit breaker panel in your home.
Initial Use 100593 - 3200 Portable Power Station 2. Press the THD Shield button 5 times within three seconds. The THD Shield disabled icon will turn on. Power Management Use the following formula to convert voltage and amperage to watts: 3. Monitor your devices for abnormal operation and disconnect as necessary. Volts × Amps = Watts To prolong the life of your Power Station and attached devices, follow these steps to add electrical load: Do Not Overload Power Station Capacity 1.
Maintenance 100593 - 3200 Portable Power Station Expandable Capacity MAINTENANCE Champion Power Station model 100593 is capable of connecting up to ten 1638 Wh external battery packs, Champion Expansion Battery model 201107. Cleaning the Power Station WARNING To order Champion Expansion Battery model 201107 to increase your Power Station’s battery capacity and run time, please call customer service at 1-877-338-0999 or visit www.championpowerequipment.com.
Specifications 100593 - 3200 Portable Power Station SPECIFICATIONS AC Charger Specifications Output Watts............................................ ......... 440 Power Station Specifications Input Voltage..................................................... 120 Power Station Model........................................ 100593 Output Voltage................................................ 55 DC Running Watts.................................................. 1600 Max. Input Amps...................
Troubleshooting 100593 - 3200 Portable Power Station TROUBLESHOOTING Problem Power Station will not turn on. No power output. Warning icons or LED light flashing. Cause Solution Battery is not charged Charge battery. Did not hold power button long enough Hold for 3 full seconds until display turns on. Battery is faulty Call Champion Support. DC Outlets overloaded Check display for flashing red 12V or USB warning light. Press Overload Reset button to restore power to outlets.
Troubleshooting 100593 - 3200 Portable Power Station Problem Cause Solution Adjust your solar panels to face the sun as best as possible throughout the day to achieve maximum charging efficiency. Unit not charging at Solar Panel rated wattage. Charging wattage depends on environmental conditions and panel efficiency. It may be necessary to connect more than any combination of 440W of solar panels to reach the full 440W of charging power.
WARRANTY* Other Exclusions CHAMPION POWER EQUIPMENT This warranty excludes: 3 YEAR or 1000 CYCLE LIMITED WARRANTY Warranty Qualifications To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.com/register To complete registration you will need to include a copy of the purchase receipt as proof of original purchase. Proof of purchase is required for warranty service.