Full Product Manual
201161 - 12,000W TRI-FUEL PORTABLE GENERATOR
OPERATION
23
4. Pull the choke knob out.
5. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails to
start within five seconds, release the switch and wait at least
ten seconds before attempting to start the engine again.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
6. Do not over-choke. As soon as engine starts, push the choke
knob in.
7. Plug in devices.
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Starting the Engine: Propane (LPG)
1. Make certain the generator is on a flat, level surface and all
circuit breakers are reset (button pushed in).
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Connect LPG hose to generator and LPG cylinder. See “Add
Fuel: Propane (LPG)” section of the manual.
4. Fully open the valve on the LPG cylinder.
5. Turn fuel select dial to the “PROPANE ON” position.
6. Pull the choke knob out.