Full Product Manual
201161 - 12,000W TRI-FUEL PORTABLE GENERATOR
OPERATION
25
4. Open Natural Gas fuel supply valve.
ON
5. Turn fuel select dial to the “NATURAL GAS ON” position.
6. Pull the choke knob out.
7. Press the ignition switch to the “START” position for 2-3
seconds.
8. Push the choke knob in.
9. Press and hold the ignition switch in the “START” position for
up to 5 seconds or until started.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can
flood and will not start.
10. If engine does not start, wait 10 seconds and repeat step 9.
11. When the engine starts, push choke knob to the “RUN”
position if in the “ CHOKE” position.
12. Plug in devices.
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Battery
NOTICE
The supplied 12V sealed lead acid (SLA) battery will recharge
while the engine is running. When the generator is not in
use for extended periods of time, it is recommended that the
battery be fully charged at least once a month with a slow
charger and disconnected when fully charged or charged using
a battery maintainer for long-term storage (not included).