Instructions / Assembly

Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical devices plugged in or turned on.
3. Turn the Fuel Valve to the ON position.
4. Flip the ignition switch to the ON position.
5. Move the choke lever to the CHOKE position.
6. Pull the starter cord slowly until resistance is felt and then pull rapidly
7. Do not over-choke. As soon as engine starts, move the choke lever to the RUN position.
Connecting Electrical Loads
1. Let the engine stabilize and warm up for a few minutes after starting
2. Plug in and turn on the desired 120 Volt AC single phase, 60 Hz electrical loads.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or
turned on.
2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and
generator.
3. Turn the Fuel Valve to the OFF position.
4. Let the engine run until fuel starvation has stopped the engine. This usually takes a few minutes.
5. Press the ignition switch to the OFF position.
Important: Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the
engine is not in use.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you need to keep your items
running.
3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra burst of power needed to start some electric driven
equipment. Following the steps listed under Power Management will guarantee that only one device will be
starting at a time.
Power Management
Use the following formula to convert voltage and amperage to watts: Volts x Amps = Watts
To prolong the life of your generator and attached devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.