Pump operates but
delivers little or no
water
1. Plugged impeller
2. Check valve
installed backwards, or
faulty
3. Pump air locked
1. Clean out impeller
2. Reverse position of
check valve, or replace
3. Drill 1/8” hole in
discharge line between
pump and check valve
Model CPS3
Submersible Sump/Effluent Pump
Thank you for purchasing this CHAMPION PUMP! The CPS3 is
a high quality, energy efficient, heavy duty cast iron 1/3 HP sump/effluent
pump. We back these Champion products with Champion service and a
Champion attitude. Please read, save, and follow these instructions to
ensure Champion performance.
Product Warranty
Date of Manufacture and Warranty Tag is on pump cord.
LIMITED WARRANTY: We warrant to our immediate customer and to the
ultimate consumer that products of our manufacture will be free of defects
in material and workmanship under normal use and service for one year
(12 months) from the date of installation, or 18 months from the date of
manufacture, which ever comes first. We will repair or replace, at our
option, to the original purchaser any part or parts of our product found
upon our examination to be defective. Please call Champion Pump
Company, Inc. (419-281-4500) for instructions. Be prepared to provide
the model number, the date code and/or serial number and proof of the
date installed when exercising this warranty. Warranty tag (Required) is on
the pump power cord. All transportation charges on products or parts
submitted for repair or replacement must be paid by purchaser. This
limited warranty does not cover products which have been damaged as a
result of accident, abuse, misuse, neglect, improper installation, improper
maintenance, or failure to operate in accordance with Champion Pump
Company, Inc. written instructions. UNDER NO CIRCUMSTANCES WILL WE
BE RESPONSIBLE FOR ANY OTHER DIRECT OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST
INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION
WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND/OR
WORKMANSHIP AND/OR DAMAGE OR DELAYS IN SHIPMENT. THIS
WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED
WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILTIY OR
FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow
limitations on how long an implied warranty lasts, or do not allow the
exclusions or limitations of incidental or consequential damages, so the
above limitations might not apply to you. This limited warranty gives you
legal rights, and you may also have other legal rights which vary from state
to state.
12-0010-0000 www.championpump.com
4 05/12
BEFORE OPERATION – Important Product and
Safety Information – WARNINGS – Personal Injury
and/or property damage could result if not adhered to.
! Risk of Electric Shock – Fatal electric shock could occur. Always
disconnect the power source before attempting to install, service,
relocate, or check the pump. Never touch pump, pump motor,
water, or discharge piping when pump is connected to electrical
power. Never enter a wet or flooded area, basement, basin, etc.
that is in contact with the pump or electrical circuit before power
supply has been disconnected.
! Pump has not been investigated for use in swimming pool areas
or any area that might reasonably expect aquatic, animal, or
human entrance. Precautions should be taken to prevent such
entrance during use.
! Connect only to a properly grounded, grounding type receptacle.
Use of a ground fault circuit interrupter (GFCI) is required for
maximum safety.
! All wiring must be performed by qualified electrician in
accordance with all local and national electric code.
! When power source or supply is turned off (in open position) a
lock and tag out should be used to prevent accidental power
application or activation.
! Do not use extension cord or cut off grounding pin. Should be
installed on separate 15 AMP circuit breaker.
! Use only with a properly sized (input AMPS, volts, HP) motor
controller.
! Do not use to pump flammable/explosive liquids such as
gasoline, fuel oil, kerosene, and /or chemicals, salt water, etc.
! Do not use pump in an explosive atmosphere or classified as
hazardous per NEC, ANSI/NFPA 70.
! Make sure pump is on hard level bottom in sump, do not set
directly on earth, gravel, or other debris. This could cause
excessive wear or possible jamming and flooding.
! Make sure pump is secure in basin and piping is firmly supported
so that pump cannot move, not allowing liquid level switch to
interfere with basin wall or other obstacle preventing proper
operation. Flooding or overheating could occur if not prevented.
!
CHAMPION PUMP COMPANY Phone: 419-281-4500
1102 Myers Pkwy Ashland, OH 44805 Fax: 419-616-1100
1